46131-0598 <90-00018>
P
AGE
17
To configure the APU remotely:
Connect RJ-11, C1, or wire-wrap pins 53, 54, and 55 of P3 to
your network. Before going to the remote site to configure the
APU, apply power to the APU. Press push button 5 on the front
of the APU until the letters “Pad” appear on the LED display if
you are going to use a programming paddle or the letters “Crt”
appear if you are going to use a dumb terminal. Connect the
programming paddle or dumb terminal at the remote site.
C
ONFIGURATION
U
SING
A
H
AND
-H
ELD
P
ROGRAMMING
P
ADDLE
1.
Apply power to the APU.
2.
Configure the paddle to communicate with the APU:
♦
Press the SHIFT, CTRL and F1 keys on the paddle at the
same time.
♦
Set the baud rate for 9600, data bits for 8, parity for none and
stop bits for 1. Use the F2 key to change the parameter and
the F1 key to change the value.
♦
When the values are set, press the F5 key to save them.
3.
Configure the ports on the APU:
♦
Press push button 5 on the front of the APU until the letters
“Pad” appear on the APU’s LED display.
NOTE:
If the APU is being configured from a remote site, press F3 on
the paddle to establish communications with the APU. When
the Main Menu appears on the paddle, press F3 again.
The Main Menu appears on the programming paddle:
F1 - TBOS
F2 - RESP
F3 - EXPB
F4 - XXXX
F5 - HELP
♦
Press Help (F5) from the Main Menu and the on-line help
appears on the screen and the function keys described below
are active.
F1 - Moves the Help screen up one line.
F2 - Moves the Help screen down one line.
F5 - Exits the Help screen.
♦
Configure the interrogator ports, responder ports, and the
expansion board as described on the next page.
4.
End of section.
INSTALLATION