background image

CAUTION

•

Install or remove modules from the shelf only when the power is off.
If you install a module in the shelf with the power on, the internal

circuitry may suffer damage and the product warranty will be void.

•

Remove and install circuit boards only in a static-safe environment
(use antistatic wrist straps, smocks, footwear, etc.).

•

Keep circuit boards in their antistatic bags when they are not in use.

•

Do not ship or store circuit boards near strong electrostatic, electromag-
netic, magnetic, or radioactive fields.

•

For more complete information on electrostatic discharge safety
precautions, refer to Bellcore

TM

 Technical Reference # TR-NWT-000870.

Copyright 1999 by Dantel, Inc. • Dantel is a registered trademark of Dantel, Inc. • ISO 9001 Registered

Printed in the U.S.A.

I

NSTALLATION

 & O

PERATION

 M

ANUAL

46023-12-0399 <90-00009>

46023-12

S

MART

 MAC

(M

ULTIPLE

 A

LARM

 C

OMBINER

)

About this Practice:

This practice has been reissued to:
• Document Surface-Mount Version

of Smart MAC.

Issue date:  March 1999

Reissued Practices: Updated and
new content can be identified by a
banner in the right margin.

UPDATED

Table of Contents

Ordering Information ............................................................................  2
General Description ...............................................................................  2
Circuit Description ................................................................................  3
Installation ............................................................................................  5
Operation .............................................................................................  10
Technical Specifications.......................................................................  11
Warranty .............................................................................................  12

46023-12

SMART

MAC

RX DATA

1

2

3

4

5

6

7

8

9

10

11

12

A

B

C

D

14

13

15

16

46023-12 REV__

Содержание 46023-12

Страница 1: ...charge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1999 by Dantel Inc Dantel is a registered trademark of Dantel Inc ISO 9001 Registered Printed in the U S A INS...

Страница 2: ...one is a 46023 12 Smart MAC all the others must be 46023 12 Smart MACs as well You cannot use the 46023 12 Smart MAC in combination with 46022 12 20 or 30 MACs Here are some features of the 46023 Sma...

Страница 3: ...d through RS 422 drivers and receivers The receive lines have an optional strap selection for 100 ohm termination The configuration of the MAP determines the data rate and proto col of each port The m...

Страница 4: ...ACE 51 54 53 42 45 44 43 36 56 55 50 45 49 47 POWER SUPPLY SUBASSEMBLY 17 35 DISPLAY DRIVER FRONT PANEL LEDs AND SWITCHES CARD SELECT CHANNEL SELECT DISPLAY CONTROL TO MATs CPMs ETC PORT 2 TX RX TX RX...

Страница 5: ...n If a channel is connected to communications lines the resistor is normally strapped IN position 1 2 If termination for a channel is provided at the source strap the resistor OUT Refer to Table A and...

Страница 6: ...source switch the resistor OFF Refer to Table B and Fig 3 TABLE B RECEIVE LINE TERMINATION SMT VERSION FIG 3 SWITCH AND STRAP OPTION LOCATIONS SMT VERSION INSTALLATION ALARM PORT NUMBER 1 2 3 4 5 6 7...

Страница 7: ...the master port data rate for 9600 baud Master Port Protocol Switches S1 5 through S1 8 Unless system requirements dictate otherwise set the master port protocol to DCPF Port Termination SMT Version O...

Страница 8: ...S2 Not Used SWITCH S3 SMT VERSION ONLY PortTermination Port 1 Terminated Port 2 Terminated Port 3 Terminated Port 4 Terminated Port 5 Terminated Port 6 Terminated Port 7 Terminated Port 8 Terminated...

Страница 9: ...ble 12 VDC Output WRT 12 VDC Output Serial Output Data 5 VDC Output MAP Channel Address 0 MAP Channel Address 2 MAP Channel Address 3 TXD Modem Data Connection MAP Channel Address 1 21 to 56 VDC Alarm...

Страница 10: ...and other functions Four green LEDs labeled A B C and D have various func tions Refer to the documentation specific to the MAP firm ware One green LED labeled RX DATA indicates that the data ports are...

Страница 11: ...sion 21 VDC 24 VDC 48 VDC 56 VDC OutputVoltageandCurrent DATA RATES MasterPort Data Port PhysicalDimensions Weight OperatingTemperatureRange VALUE 21 to 56 VDC 300 mA 268 mA 155 mA 140 mA 133 mA 120 m...

Страница 12: ...en instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respec...

Отзывы: