Dantel 46018 Скачать руководство пользователя страница 9

46018-0198 <90-00007>

 P

AGE

 9

OPERATION

T

here are no specific operating instructions for the 46018

Audible Alarm Module. The unit begins operation with

application of power.

The audible level is user-adjustable from the front panel. Refer
to Fig. 5.

46018-01

FOUR LEVEL

AUDIBLE

ALARM

A11-56018-01 REV__

OUTPUT

EXT

LEVEL

ADJ

TECHNICAL SPECIFICATIONS

DESCRIPTION

Input Voltage Range
Input Current

Idle
Enabled

Heat Dissipation

Idle
Enabled

Speakers
Amplifier Output Level
Temperature Range
Physical Dimensions
Weight

VALUE

-21 to -56 VDC

30.05 mA
57.7 mA

4.99 Btu/Hr.
9.45 Btu/Hr.
250 mW adjustable
+7 dBm adjustable
0° to 60° C.
1.4" x 6.0" x 5.6"
5.75 ounces

F

IG

. 5 - F

RONT

 P

ANEL

 V

IEW

, 46018

Содержание 46018

Страница 1: ...ecautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1998 by Dantel Inc Dantel is a registered trademark of Dantel Inc ISO 9001 Registered Printed in the U S A INSTALLATION OPERAT...

Страница 2: ...evels according to priority The 46018 Audible Alarm features Four four pin inputs Two eight position DIP switches for setting module tone fre quencies and duty cycles A strap option which allows selec...

Страница 3: ...on of input 1 overrides activation of inputs 2 3 or 4 for alarm priority purposes Input 1 automatically switches to the most important alarm levels A Function Generator The frequency tones route to a...

Страница 4: ...4D 3A 3B 3C 3D 2A 2B 2C 2D 1A 1B 1C 1D INPUT 4 INPUT 3 INPUT 2 INPUT 1 EXTERNAL OUTPUT GROUND 21 TO 56 VDC VOLTAGE REGULATOR 20 VDC S1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 S2 IC 1 20 VDC EXT TP1 TP2 IC3 I...

Страница 5: ...LE UPDATED 46001 XX A B C D 1 4 7 2 5 8 0 3 6 9 SP SETUP NEXT F1 F2 DISPLAY MODE ACO GLB LOC NOR TST ACK GLOBAL LOCAL CRITICAL MAJOR MINOR STATUS ENTER DANTEL 460 STATUS MONITOR CRI MAJ MIN ACO ADU ST...

Страница 6: ...the module in the equipment shelf and checking out the module 1 Set the strap and switches The strap selects the output waveform sawtooth or square which varies the alarm s audio tone The option switc...

Страница 7: ...ing performed on this module When it is determined during checkout that the module has malfunctioned it is to be replaced and returned to the factory for repair INSTALLATION WAVE SHAPE Saw tooth Wave...

Страница 8: ...2 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 CIRCUIT SIDE OF PC BOARD COMPONENT SIDE OF PC BOARD 20 VDC Output External Output External Output 21 to 56 VDC 2D...

Страница 9: ...o Fig 5 46018 01 FOUR LEVEL AUDIBLE ALARM A11 56018 01 REV__ OUTPUT EXT LEVEL ADJ TECHNICAL SPECIFICATIONS DESCRIPTION Input Voltage Range Input Current Idle Enabled Heat Dissipation Idle Enabled Spea...

Страница 10: ...nstrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respective...

Отзывы: