46018-0198 <90-00007>
P
AGE
7
T
ABLE
A - S
TRAP
O
PTIONS
, 46018
T
ABLE
B - S
WITCH
O
PTIONS
, 46018
2. Wire the pin connections.
Wire the connector into the shelf or housing. Refer to Fig. 4.
3. Install the module in the proper slot in the equipment
shelf.
4. Checkout
To check the operation of the 46018 AA, monitor the unit in a
system:
1.
Apply an alarm (ground) at each input being used and observe the
front panel for proper operation. The front panel “LEVEL ADJ”
button (R26) adjusts the audio output level of the two panel speak-
ers.
2.
Monitor the audio output at the front panel test points TP-1 and
TP-2. Connect a 600 ohm level meter across the test points.
3.
The meter reads -23 dBm to +7 dBm as you vary the “LEVEL
ADJ.” Set the gain for the front panel speaker levels. Refer to
Fig. 5.
4.
There is no troubleshooting performed on this module. When it is
determined during checkout that the module has malfunctioned, it
is to be replaced and returned to the factory for repair.
INSTALLATION
WAVE SHAPE
Saw-tooth Wave
Square-wave
STRAP
L
H
TONE OPTION
800 Hz. Pulsating Tone
1025/1800 Hz. Shifting Tone
90/1320 Hz. Shifting Tone
550/1350 Hz. Shifting Tone
Fast Repetition, 1/6 sec. off,
1/3 sec. on
Slow Repetition, 1/2 sec. off,
1 sec. on
60/850 Hz. Shifting Tone
INPUT #1
S2-5, S2-6,
S2-7 all OFF
S2-5 ON
S2-6 ON
S2-7 ON
S2-8 ON
INPUT #2
S2-1, S2-2,
S2-3 all OFF
S2-1 ON
S2-2 ON
S2-3 ON
S2-4 ON
INPUT #3
S1-5, S1-6,
S1-7, S2-8 all OFF
S1-5 ON
S1-6 ON
S1-7 ON
S1-8 OFF
S1-8 ON
INPUT #3
S1-1, S1-2,
S1-3, S2-4 all OFF
S1-1 ON
S1-2 ON
S1-3 ON
S1-4 OFF
S1-4 ON
NOTES:
1. Other than the switch listed (which can be either ON or OFF) the status of all other
switches is assumed to be OFF.
2. The frequencies shown in Table B are approximate. Any combination of S1 and S2 switch status can
result in other tone frequencies being produced.