4. Menu Setup Instruction

   

1.

 

Menu basic operation 

a) 

Use  keyboard  or matrix  to  adjust  No.  64  pre-sets  or  adjust  the  No.1  pre-sets  twice 

within four seconds, the main menu will be open. 

b) 

After  the menu  is  on  the  screen,  if  use keyboard,  you  can  control  joystick  to  move 

cursor, turn up or down to move cursor to the item that need set, turn it left or right to 

amend the contents or enter this item to set; If use matrix, operate 

TILT UP

TILT 

DOWN

  to  move  cursor  to  the  item  that  need  set,  operate 

PAN  LEFT,

PAN 

RIGHT

  to amend the contents or enter the item to set. 

c) 

Thermal  camera  has  the  function  of  memory  and  data  will  not  lose  settings  when 

power off.    Main set of the menu, please refer to the menu setup. 

2.

 

Menu Setup 

2.1  MAIN MENU   

2.1.1  DISPLAY SETUP: Enter the submenu of screen 

display  set.  You  can  set  ID  display,  pre-setting 

point title display and camera self display. 

2.1.2  CAMERA  SETUP:  Enter  the  submenu  of 

camera parameter set 

2.1.3  CONTROL  SETUP:  Enter  the  submenu  of 

thermal camera control parameter set. 

2.1.4  THERM  IMAGE  SET:  Enter  the  submenu  of 

thermal  image,  which  is  displayed  on  both 

videos. 

2.1.5  PROGRAM: Enter the submenu of thermal camera enhancement function. 

2.1.6  NTSC CAMERA: NTSC current mode. 

2.1.7  CAM DEFAULT SET: Recover the camera’s default. 

2.1.8  RESET PT: Recover the system. 

2.1.9  EXIT: Exit the main menu. 

 

MAIN MENU 

= = = = = = = = = = = = = = = =   

DISPLAY SETUP 

CAMERA SETUP 

CONTROL SETUP 

THERM IMAGE SET 

PROGRAM 

NTSC CAMERA 

CAM DEFAULT SET 

RESET PT 

EXIT 

Содержание DLS1798LA3Q9

Страница 1: ...DLS1798LA3Q9 Thermal PTZ Camera Installation and Operations Manual Model Number DLS1798LA3Q9 Description Thermal and 36x CCD PTZ Camera...

Страница 2: ...Please read this operation manual carefully before using it as it can provide you with correct technical information on how to properly do the installation Please contact us if you come across problem...

Страница 3: ...e contact factory and remember not to try and repair it without instructions from Dante 6 In order to protect the device and people this device need to be installed on firm flat area 7 Please install...

Страница 4: ...ection Reference 11 Part Three Operation Introduction 12 1 Function Introduction 12 2 Cam Protocol and Address Setting 13 3 Baud Rate Setting 15 4 Protocol Setting 15 Part Four Quality guarantee and a...

Страница 5: ...lind spot monitoring and high accurate orientation high intelligent easy to operate and maintain smart shell with professional design light firm thermo stabilization anti corrosion waterproof and acid...

Страница 6: ...gth f 3 4 122 4mm Signal to noise 50db Video output VBS 1 0Vp p simultaneous negative Y C output Lowest illumination 0 01Lx Electronic shutter 1 1 1 10000s Simultaneous system Simultaneous inside or o...

Страница 7: ...ings when power off Main set of the menu please refer to the menu setup 2 Menu Setup 2 1 MAIN MENU 2 1 1 DISPLAY SETUP Enter the submenu of screen display set You can set ID display pre setting point...

Страница 8: ...he tenth line When display CROSS or GRID title will be show on the first line 2 2 5 CAM DISPLAY If this item is ON the camera s self display will be open 2 2 6 CROSS DIS Screen appears cross in the ce...

Страница 9: ...camera is in a state of patrolling it will not return to HOME When the camera doesn t need to return to HOME please set this item in OFF 2 4 2 2 HOME POS HOME is the return point For example you need...

Страница 10: ...ust the monitoring position Push CLOSE key to save the current position and return 2 6 3 RUN AUTO PAN Press OPEN to start scan function and exit the menu Before running please first set up the start p...

Страница 11: ...r Continuously push it for one second will accelerate Push CLOSE key press to leave the edit state and save the amendment The program will search the first POS with the position of and will save the f...

Страница 12: ...conditions 1 2 Anti jamming Keep the night vision camera far away from the radio transmitters radar transmitters and other high frequency devices Adopts electromagnetic shield when necessary 1 3 Wate...

Страница 13: ...hexagon bolt and four M10 nut to fix the night vision camera onto customer s plate Below is the size of night vision camera s fix hole 3 2 After installation please connect the aviation plug pinout we...

Страница 14: ...e Then please separately connect brown and blue wire to 12V 24V power supply box s output Control and Video Output Cable Nine cores aviation outlet definition as follows you can also see the marks on...

Страница 15: ...ght length Please use the power supply that supplied Or else it would cause no operation of the camera Avoid shaking and extrusion during fixing for protecting key components and optics inside Signal...

Страница 16: ...ch between color and black white when light outside is higher than setting the camera is in a state of color b When open No 1 assistant switch can use TELE WIDE to control CCD cam s zoom The default i...

Страница 17: ...n function call No 229 presetting bit to run line scan function d Character adding function after self checking Address Protocol Baud Rate will be shown on the screen Presetting No will be shown on th...

Страница 18: ...OFF 5 ON OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7 ON ON ON ON ON OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF 9 ON OFF OFF ON OFF OFF OFF OFF 10 OFF ON OFF ON OFF OFF OFF OFF 11 O...

Страница 19: ...s follows 3 Band Rate Setting 2400bps 4800bps 9600bps 19200bps optional using the ninth and tenth dip of DIP Switch J16 to set up the band rate shown as below Band Rate Dip Switch J16 DIP 9 DIP 10 240...

Страница 20: ...ity guarantee and after sales service 1 Quality Guarantee and After sales Service Dante Security warrantees product for 12 months from date of Customer receipt of equipment Extended warranty is availa...

Страница 21: ...C connectors Video camera is damaged change after self inspect but cannot control Wrong connection of control signal correct Wrong match of address Reset the controller s address Wrong match of protoc...

Страница 22: ...Farthest Transmission Distance 2400 Bps 1800m 4800 Bps 1200m 9600 Bps 800m 3 Connection and terminal resistance RS 485 industry line requires chain connection among all devices and both ends should be...

Страница 23: ...farthest two devices As following sketch 1 and 15 can t accord with RS 485 it result to signal reflection and anti jamming ability reduction Regarding this problem we recommend to use RS 485 Divider...

Страница 24: ...3 0 090 39 43 0 00636 0 100 38 42 0 00785 0 110 37 41 0 00950 0 130 36 39 0 01327 0 140 35 0 01539 0 160 34 37 0 02011 0 180 33 0 02545 0 200 32 35 0 03142 0 230 31 0 04115 0 250 30 33 0 04909 0 290 2...

Страница 25: ...21 1 000 18 19 0 7854 1 250 16 18 1 2266 1 500 15 1 7665...

Отзывы: