Dante DFG480000 Frame Скачать руководство пользователя страница 26

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4.6 Power Budget Calculations for DFG48000

 

PM’s with Fiber Media 

Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power 
budget. To calculate the power budget of different fiber media installations using DFG48000 products, 
the following equations should be used: 
OPB (Optical Power Budget) = PT (min) - PR (min) 
where PT = Transmitter Output Power, and PR = Receiver Sensitivity 
Worst case OPB = OPB - 1dB (for LED aging) - 1dB (for insertion loss) 
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] 
where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km, 
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km 
 

5.0 Introduction - DFG48000

 

Managed Fiber Switch Port Modules

 

This chapter describes each Port Module (PM), including appearance, functionality, and status 
displays. 

5.1 Inspecting the Package and Product 

This section applies only to PMs shipped as separate items, i.e., DFG480XX Cards (Port Modules) not 
factory installed in a DFG48000 PM slot. Examine the shipping container for obvious damage prior to 
installing a DFG480XXPM; notify the carrier of any damage you believe occurred during shipment or 
delivery. Inspect the contents of this package for any signs of damage and ensure that the items 
listed below are included.  This package should contain: 
One (1) or more DFG480XX Cards with installation instructions and illustrations.  Remove the 
DFG480XX (s) from the shipping container. Be sure to keep the shipping container should you need to 
ship any of the PMs separately at a later date. In the event there are items missing or damaged, 
contact your supplier. If you need to return the unit, use the original shipping container if possible. 
 

5.2 DFG480XX Card (Port Module) Description 

An important feature of the DFG48000 is the use of Port Modules for flexible mixed-media 
connectivity to RJ-45 and fiber media. Since the DFG48000 Switches have dual-speed capability for 
copper ports, the 6 or 8-port interfaces are designed to support all standard Ethernet media types at 
10 or 100Mps speed. Each DFG480XX PM provides six or eight ports for connecting Ethernet 
segments with its individual connector type and media. For a list of DFG480XX Port Module types, 
refer to Section 1.2 
Each DFG480XX PM is individually described in the following sections.  

NOTE:

 The port #1 on the RJ-45 ports on all the modules, either all RJ-45 ports or used for COMBO 

module is set as (=) other user ports. 
 

5.2.1 DFG380XX, 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-ST “twist lock” 
Combo Module 

The DFG380XX is a combo 6 port module of RJ-45’s at 
10/100Mbps and fiber optic ports at 100MB.  
The Combo module is equipped with dual mode 
ST-type connectors and dual speed copper ports.  
The ST-connector functions as a fiber optic  
transceiver to support 100BASE-FX network 
segments. When installed in a  
DFG48000 Managed Switch, the copper port 
supports the standard distance 100m  
on each port and the fiber port supports 
fiber optic cable distances up the IEEE-standard  
100Mbps distance limits, i.e., typically 2km at  
Full-duplex and 412m at half-duplex.  Each port has an Activity 
(ACT) LED indicating packets being received, a 
Link (LK) LED that indicates proper connectivity  
with the remote device when lit, and 
FDX/HDX LED to indicate full-duplex mode  
when lit (or half-duplex when off).  
The 10/100 LED indicates the speed,  
if the LED is ON 100Mbps if it is OFF 10Mbps. 

 

 

 

Содержание DFG480000 Frame

Страница 1: ...FG48000 Ethernet Managed Switch Installation and Operations Manual Model Number DFG480000 Frame DFG48044XEYRC DFG48044XFYRC DFG48G022XEYRL DFG48G024XEYRL Description Fiber Optic Ethernet Managed Switc...

Страница 2: ...better 15 3 3 Table Top or Shelf Mounting 16 3 3 1 Rack mounting 17 3 4 Powering the DFG48000 Managed Fiber Switch 18 3 4 1 Alarm Contacts for monitoring internal power and Software Traps 18 3 5 DFG48...

Страница 3: ...13 4917 Website http www dantesecurity com Email support danteSecurity com Federal Communications Commission Radio Frequency Interference Statement This equipment generates uses and can radiate freque...

Страница 4: ...col IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1q VLAN Tagging IEEE 802 3x Flow Control Maximum 10 Mbps Ethernet Segment Lengths Unshielded twisted pair 100 m 328 ft Shielded twisted pair 150 m...

Страница 5: ...85 C Ambient Relative Humidity 5 to 95 non condensing Altitude 200 to 13 000 ft 60 to 4000m Conformal Coating option on Z models Packaging Enclosure Rugged High strength metal Suitable for stand alon...

Страница 6: ...Switch base unit May be configured with a selection of 10 100 1000 DFG480XX fiber and copper port connector types Wire speed filtering and forwarding across all ports 802 3x flow control 802 1p priori...

Страница 7: ...which may be configured as fiber ports but still offers a space saving rack mount chassis that is only 1U 1 70in or 4 32cm high The mixed media capability allows user selection of all popular flavors...

Страница 8: ...able using the 4 slots allows the DFG48000 to efficiently serve a large variety of applications especially using fiber media The DFG480XX port modules are normally factory installed but may be changed...

Страница 9: ...er modules behave the same as the 8 100Mb ST fiber modules except for the 10Mb speed For ports numbering ports 1 2 5 6 are present ports 3 4 7 8 are not present The default setup on the 10Mb fiber mod...

Страница 10: ...hile up to two Gigabit modules maxm can be configured in the modular slot The Gigabit port option for the modular slot comes in couple of different configuration The Giga port has been offered as sing...

Страница 11: ...tches Each frame or packet is loaded into the Switch s memory and inspected before forwarding can occur This technique ensures that all forwarded frames are of a valid length and have the correct CRC...

Страница 12: ...lect the desired mix of port types speeds The port modules are normally factory installed and tested but may be changed in the field Rack mounting may be standard or reverse 19 inch or ETSI or 23 Telc...

Страница 13: ...witch makes it an attractive choice for use in applications with LAN connections to an organization s multiple site offices The different offices can be easily connected together with the Fiber ports...

Страница 14: ...on of the DFG48000 Switches as well as connection of the various Ethernet media types 3 1 Locating DFG48000 Switches The location of a Dante Security DFG480XX Switch is dependent on the physical layou...

Страница 15: ...tors Single mode fiber cable has a smaller diameter than multi mode fiber cable 9 125 microns for single mode 50 125 or 62 5 125 microns for multi mode where xx xx are the diameters of the core and th...

Страница 16: ...its are 1U 1 75 high When properly installed the front mounted LED status indicators should be in plain view and easy to read Rack mount installation requires special 19 rack mounted brackets and scre...

Страница 17: ...re used for status visibility in the front of the unit showing the same data There are three options of brackets available to mount in the standard 19 frame or the 23 frame or ETSI 21 frame The 19 bra...

Страница 18: ...re Alarm operated by user settings in the DFG48000 software The user can disable the Software Alarm feature with a software configuration command if desired When the Software Alarm is enabled the Form...

Страница 19: ...tep2 Remove Chassis Cover The DFG48000 chassis are combined with top and bottom parts and assembled together with the help of 22 Philips head screws There are 7 screws located on the front bottom and...

Страница 20: ...rd as shown in fig 3 5 2a and 3 5 2b on the chassis built in stand off female provided at the front of the DFG48000 Main Board and screw down tightly with the three 5 16 stand off male on the top of t...

Страница 21: ...er the slot opening in the front panel This will maintain proper cooling air flow safety and operation as required by FCC CE and other regulations Step5 Once the latching connectors are aligned proper...

Страница 22: ...king the speed F H and activity status 3 5 3 Removing DFG480XX Cards To properly remove a card from the DFG48000 Managed Fiber Switch follow the 3 steps below Step1 Remove chassis cover See procedures...

Страница 23: ...aged station a PC or Console terminal to connect directly to the switch using a straight through cable Note The Null Modem DB 9 cable is optional and can be order from the factory along with the unit...

Страница 24: ...dresses suitable for use in larger networks They are self learning so as nodes are added removed or moved from one segment to another the DFG48000 Switch automatically keeps up with node locations An...

Страница 25: ...domain The Path Delay Value PDV bit times must account for all devices and cable lengths within that domain For DFG48000 Fast Ethernet switched ports operating at 100Mb half duplex the bit time delay...

Страница 26: ...your supplier If you need to return the unit use the original shipping container if possible 5 2 DFG480XX Card Port Module Description An important feature of the DFG48000 is the use of Port Modules f...

Страница 27: ...he 10Mb ST fiber ports allow the user to connect their legacy 10Mb network to the DFG48000 switch They also provide a convenient way for the half Duplex hub to connect to the switch through 10Mb fiber...

Страница 28: ...s much as 20 Km each port has an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and a FDX HDX LED to indicate full...

Страница 29: ...45 and 1 100Mb single mode FX LC Small Form Factor The DFG48G024EYRL 4 port Module is a combo module with copper and fiber Small Form Factor LC type fiber ports The small size of LC connectors give an...

Страница 30: ...it Be certain that each AC power cord is plugged into a functioning electrical outlet Use the PWR LEDs to verify each unit is receiving power 4 If the problem is isolated to a network device other tha...

Страница 31: ...you use the original container if available Units should be wrapped in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide CAUTION Do n...

Отзывы: