ELECTRICAL WIRE DIAGRAM
The Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical shorts,
consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
230V, 7.2AMP, 50HZ, 1650W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
INDEX
W : WHITE
R : RED
K : BLACK
G : GROUND
GROUNDED
POWER CORD
VW-1, 105°C/221°F,
18-3 STANDARD CSA
TEMPERATURE
PROBE
TEMPERATURE PROBE
MOLEX CONNECTORS
EXTERIOR VIEW
CONTROL BOARD
INTERIOR VIEW
GROUND
HEATING ELEMENT
230V, 7.2AMP, 1650W
K
W
G
G
W
R