PROBLEM
CAUSE
SOLUTION
No Power Lights
On The Control
Board
Power Button
Press the Power Button. Try another attempt and hold for two seconds to verify connection.
Not Connected To
Power Source
Ensure smoker is plugged into a working power source. Reset breaker. Ensure GFCI is the
correct power supply (see
Electric Wire Diagram
for access to electric components). Ensure
all wire connections are firmly connected and dry.
Faulty Control Board
Control Board needs to be replaced. Contact Customer Service for a replacement part.
Power Light
Not On
Unit Not Turned On
Press the Power Button. Try another attempt and hold for two seconds to verify connection.
Faulty Control Board
Control Board needs to be replaced. Contact Customer Service for a replacement part.
No Display On
Control Board,
Power Light Is On
Faulty Control Board
Control Board needs to be replaced. Contact Customer Service for a replacement part.
Element (Heating)
Light Not On
TEMP / TIME Not Set
Set the TEMP and TIME on the Control Board to turn on the heating element light.
Faulty Control Board
Control Board needs to be replaced. Contact Customer Service for a replacement part.
TEMP / TIME Will
Not Adjust
Faulty Control Board
Control Board needs to be replaced. Contact Customer Service for a replacement part.
Temperature In
Main Cabinet Is
Inaccurate
Temperature
Probe Is Dirty
Follow
Care and Maintenance
instructions.
Temperature
Probe Not Making
Connection.
Access the electrical components on the base of the unit (see
Electric Wire Diagram
) and
check for any damage to the Temperature probe wires. Ensure Temperature Probe spade
connectors are firmly connected, and connected correctly, to the Control Board.
Faulty Control Board
Control Board needs to be replaced. Contact Customer Service for a replacement part.
Unit Takes
Too Long /
Excessive Time To
Achieve Desired
Temperature
Cold Climate
Outdoor temperature is below 65°C / 18°F, so the unit may take extended heating time.
Extension Cord Used
Using an extension cord may reduce the power supply to the unit. Plug the appliance
directly into power source or ensure maximum length extension cord is 7.6 meters / 25 feet,
minimum gauge 12/3.
Cabinet Is Too Packed There is too much food in the cabinet. Place food on the cooking grids, leaving room
between each item to allow smoke and moisture to circulate evenly.
Door Not Closed
Ensure door is closed, seal is not damaged, and the door latch is secure.
Water Pan Not
Properly Located
Check the water pan to ensure it is sitting properly on the support brackets. See
Assembly
Instructions
for further instruction.
Faulty Control Board
Control Board needs to be replaced. Contact Customer Service for a replacement part.
Door Not Closing
Properly
Poor Door Alignment Adjust door hinges to ensure that door is mounted correctly. See
Assembly Instructions.
Damaged Door Seal
Door needs to be replaced. Contact Customer Service for a replacement parts.