background image

 6 

H

H

OW

OW

 

 

Y

Y

OUR

OUR

 

 

A

A

PPLIANCE

PPLIANCE

 

 

W

W

ORKS

ORKS

 

Cautions

:  

 

Do not try to operate your stove with viewing door open. Pellets will not feed under these       
circumstances and a safety concern may arise from sparks or fumes entering room. 

 

If you are not drawing combustion air from outside, care must be taken to allow for adequate air 
make up, to avoid possible room air starvation when stove or other exhaust fans are in           
operation. 

 

It is highly recommended that you install a high quality 

smoke detector 

as well as a 

carbon 

monoxide gas 

detector in the room where stove is installed. Care should be taken to make 

sure detectors are in working order at all times. 

Fuel in the form of wood pellets , shelled corn or grain  is stored in the hopper.  An 
auger delivers the pellets to the burn grate.  The fuel rate, or heat output, is set by 
adjusting the feed rate touch pad, (settings 1 to 4).  A fan provides combustion air to 
the burn grate.  The amount of combustion air in the burn grate is adjustable and 
automatically changes as the fuel rate changes.  The higher the fuel rate, the larger 
the amount of combustion air and visa versa.  The fuel burns in the burn grate,     
producing heat. Some heat radiates out the front of your stove.  The majority of the 
heat passes around the heat exchange tubes and air plenum around the firebox and 
is then moved into the room by the room air fan. A small amount of heat must pass 
out the exhaust of your stove, along with gases, into the atmosphere.  

 

Your stove's heat output can be adjusted from setting 1-4, through the FEED RATE 
touch pad, to vary your heat 
output from Low to High. 
The room air fan can be 
manually adjusted through 
the FAN SPEED to run 
faster or slower to             
correspond to the amount of 

heat being produced. The room air fan is also on a 
limit switch, controlled to run on high when the stove 
reaches higher temperatures and then resume the 
speed you had selected once it cools to a lower     
temperature.   

      

Your stove can run efficiently over extended periods of 
time and at different heat output levels as long as the 
fuel supply is uninterrupted and 

timely cleaning and 

maintenance is preformed

.    An example of how 

improper cleaning effects operations is; the  
exhaust pressure switch will shut the pellet  supply off 
and your stove will shut off if the   exhaust system be-
comes plugged. 

The operations and maintenance of your 

Glow Boy 

Series of multi-fuel appliance are unique 

and 

should not be considered to be like a wood, coal, gas, electric, propane or oil heater, stove or appliance. 

FUEL CONSIDERATIONS 

Your 

Glow Boy 

Series of Multi-fuel appliance

 i

designed to burn the following: 

1. 

Wood pellets that comply with the Pellet Fuel Industries standards.  

2. 

A combination of up to 50/50 Wood Pellet and Shelled Corn   

3. 

100%  Shelled Corn or Grain, using the Multi—Fuel Grate, and manual start only,  No Igniter. 

Window

Burn Pot

Burn Grate

Heat Tubes

Tube Scraper

Ash Pit

Hopper

Fan Motors

Auger

Exhaust

Air Intake

Auger Motor

Base

Hopper Lid

 

as desired

as desired

Memory &

Fan Trim

Glow Boy  Home & Shop Heater

               www.glowboystoves.com                6

 

Содержание Home Heater HGBH1

Страница 1: ...OR EVEN DEATH Installation shall conform to CAN CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment in Canada and NFPA 211 Chimney Fireplaces Vents and Solid Fuel Burning Appli...

Страница 2: ...greatly from company to company from load to load and occasionally from bag to bag 4 Be extra 5 Remember that most operational dilemmas with a pellet stove are usually traced back to Improper installa...

Страница 3: ...YPE 10 HOPPER CLEAN OUT CHUTE 37 SAFETY PRECAUTIONS LIMITED WARRANTY 38 DETERMING SIZE DISTANCE 11 SERVICE MAINTENANCE LOG 39 TERMINATION 12 PLANNING OUTSIDE AIR 13 APPLIANCE PLACEMENT 14 FLOOR PROTEC...

Страница 4: ...pliance Keep all such liquids well away from the appliance while it is in use This heater must be connected to a standard 115 V 60 Hz 3 prong grounded electrical outlet in accor dance with local build...

Страница 5: ...in a metal container with a tight lid and placed on a non combustible surface or on the ground well away from all combustible materials pending final disposal The exhaust system should be checked twic...

Страница 6: ...stove along with gases into the atmosphere Your stove s heat output can be adjusted from setting 1 4 through the FEED RATE touch pad to vary your heat output from Low to High The room air fan can be...

Страница 7: ...Your pellet appliance has a high temperature limit switch installed If the temperature at the back of the firebox reaches approximately 250 F the switch will shut off the electricity going to the Vac...

Страница 8: ...pply ex ceeding 35 1 by ratio are exempt from EPA regulations PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE Heating capacity will vary depending on floor plan layout of your home degree of insulation an...

Страница 9: ...hand for warranty COMPLETE THIS CHECK LIST WHILE INSTALLING YOUR MULT FUEL APPLIANCE _____ Carefully read the ENTIRE installation section first Twice is better _____ Read the Installing Freestanding I...

Страница 10: ...al runs These Tee s are to assist in periodically cleaning the vent Single or Double clean out tees may be used The exhaust system must be installed so the entire system can be cleaned without disasse...

Страница 11: ...uivalent and the Altitude above sea level NOTE In some cases it may be necessary to contact Dansons Customer Service personal to determine acceptable venting configurations and altitude adjustments 1...

Страница 12: ...Minimum 1 clearance above any door or window that opens C Minimum 3 clearance from any adjacent building D Minimum 7 clearance above any grade when adjacent to public walkways E Minimum 2 clearance ab...

Страница 13: ...t 1 foot away from the exhaust system termination When outside air is taken from an existing chimney the exhaust system must not terminate in the same chimney The outside air pipe on your stove is 2 O...

Страница 14: ...on Alcove Installation Stove and floor protection must be installed on a level secure floor NOTE It is important for your appliance to be level Leveling should occur below the floor protection pad The...

Страница 15: ...epth depending on the brand of PL vent used Before placing the stove connect the Tee and measure off the 3 clearance ALCOVE INSTALLATION Minimum clearances to combustibles Figure 14 15 2 inch from bac...

Страница 16: ...s Flashlight Wire stripper and wire cutter Hammer Bubble Level Utility knife Adjustable pliers 6 to 8 inches Small hand broom and dustpan Furniture and Floor Protection Supplies Caulking tube of RTV H...

Страница 17: ...nuts supplied and secure tightly 6 Place a bead of RTV silicone around the end collar of the Quick Connect of your stove s exhaust C Firmly push the PL vent pipe adaptor J into the bead of RTV silico...

Страница 18: ...t outside air source with a inch screen over the inlet Figure 26 B C D For transportation all chimney vent above the mobile home must be removed Chimney PL Vent must be 3 or 4 PL Vent and must extend...

Страница 19: ...case of power failure Follow the same basic steps in locating your appliance attaching the exhaust system and outside air intake to your stove as the previous examples 1 2 3 4 5 6 7 8 Main Floor Vert...

Страница 20: ...lf Tapping Screws x 27 7 6 24 8 PL Clean Out Tee Cap PL Length of Pipe PL 90D Elbow PL Wall Thimble 10 11 12 1 2 3 4 5 Cleanout Door 9 10 11 Main Floor Class A Tie In 1 Pipe Adapter Clean Out Tee Cap...

Страница 21: ...ver FINE TUNNING YOUR STOVE later in this manual OPENING AND CLOSING THE MAIN DOOR Open the stove door by rotating the handle COUNTER CLOCKWISE toward the TOP of the stove until the handle is about th...

Страница 22: ...mal operating temperatures your stove will continue to run If the fire does not light and or burn properly the electricity to your stove s components will be shut off at the end of 15 minutes The FAN...

Страница 23: ...4 Lights Feed Rates 3 4 Feed Rates 1 4 Only be concerned with the lights All others do not effect the mode selection process FEED RATE NOTE The Starting Point of the cycle depends on what mode the con...

Страница 24: ...t 1 cycle When the temperature in the room drops to the level set at the thermostat the stove will again cycle to the HIGH 2 3 or 4 preselected set ting For optimum heat transfer the FAN setting shoul...

Страница 25: ...e stove off Feed Rates 1 2 U UNDERSTANDING NDERSTANDING T THE HE C CONTROL ONTROL HI MED LOW FAN SPEED OFF FAN SPEED AUGER CYCLE Glow Boy Home Shop Heater www glowboystoves com 25 FINE TUNE ADJUSTMENT...

Страница 26: ...D RATE or START touch pad The COMBUSTION FAN exhaust will start and operate at full speed for 60 seconds then adjust downward to match feed rate 1 The CONVECTION FAN heating will start and the LED wil...

Страница 27: ...LET DAMPER This will have to be set as the factory can not send the units out with the damper pre set This is done to accommodate a wide range of installations elevations and fuel type and quality Sli...

Страница 28: ...put and visa versa Pellet feed rate at the same fuel settings may vary greatly from brand to brand and may vary somewhat from batch to batch within the same brand FINES FINES in pellets are pieces of...

Страница 29: ...ext heating season unless properly stored If you do decide to carry it over make sure to check the corn for proper moisture content FACTORS EFFECTING FEED RATES Generally the smaller and cleaner free...

Страница 30: ...rn Pot as well BURN POT A COLD STOVE ONLY Remove the burn grate Clean out the burn pot area of all debris CAUTION When replacing the grate make sure it fits properly in the burn pot WINDOW CLEANING CO...

Страница 31: ...the grate DOOR GASKET Inspect the main door gasket periodically The main door may be removed to have frayed broken or compacted gaskets replaced EXHAUST VENTING The by products of combustion contain s...

Страница 32: ...gar and water solution along with a rag Oven cleaner and window cleaners will leave a film on the glass that will attract smoke and creosote like a magnet Should a build up of creosote or carbon accum...

Страница 33: ...BLEM CAUSE SOLUTION Stove Will Not Start 1 No electrical power Ensure the stove is plugged in to a 120VAC electrical outlet and a Surge Protection unit Check outlet for electrical power and proper vol...

Страница 34: ...Remove all ash and clinkers Ensure air holes are free of debris or build up 3 Igniter is not glowing Remove burn grate close door and re start the appliance If the igniter does not glow red inside the...

Страница 35: ...or smoke smell spillage 1 Exhaust System Hi Heat RTV silicone all joints even manufactured Ensure venting is gas tight Inspect exhaust fan and gasket area ensure a tight fit Proper maintenance and cl...

Страница 36: ...aft Assembly KS5080 1240 Burn Grate Super Grate KS5020 1040 Combustion Fan w gasket KS5020 1070 Convection Fan w gasket KS5040 1090 Control Board AcuTron 2 Door Assembly black Door Assembly brass trim...

Страница 37: ...o the inside of the appliance remove the hex screws from the LEFT HAND SIDE PANEL looking from the front of the heater These are located on the back left hand side corner of the appliance Remove the p...

Страница 38: ...Burning other than quality wood pellets may void the warranty The warranty does not cover damage or breakage due to misuse improper handling or modifications The limited warranty registration card mu...

Страница 39: ...NE PURCHASE DATE INSTALL DATE INSTALLED BY STOVE MODEL SERIAL NUMBER WAS UNIT PRE BURNED SPECIAL COMMENTS SERVICE DATE TECHNICIAN DESCRIPTION OF WORK DONE S SERVICE ERVICE M MAINTENANCE AINTENANCE L L...

Страница 40: ...40...

Отзывы: