Danish Interpretation Systems DCS 600 Скачать руководство пользователя страница 10

Danish Interpretation Systems 

 

User Manual 

 

Manual 01 18 04440

 

10

Channel setup menu 

If the “Channel setup” entry is chosen the Channel 
menu
 is shown: 

 

 

 

An  entry  can  be  changed  by  selecting  it  with  the 
select keys. This is marked by an ”>” to the left of 
the entry: 

 

 

 

Now the language can be toggled up or down with 
the  arrow  keys.  The  change  is  accepted  with  the 
ENTER key or discarded with the MENU key. The 
channel can be adjusted between “Floor 2, Floor 1, 
Floor”  as  the  lowest  channel  up  to  the  number  of 
open interpreter channels.  

The Channel menu is left with the MENU key.  

 

Floor output 

There are 3 floor outputs available at the Channel 
menu: 

Floor 

Automatic gain controlled output 

Floor 1 

Loudspeaker audio, unregulated 

Floor 2 

Loudspeaker audio, regulated 

Volume setup menu 

By  pressing  the  Volume  button  from  the  Set-up 
menu the user gains access to the Volume menu

 

 

 

 

From this menu it is possible to change the volume 
setting for each channel individually from -40 dB to 
+15  dB  in  steps  of  1  dB.  When  selecting  Off  the 
output is muted.  

The volume level for a specific output is changed in 
the  same  way  as  the  language  setting  by  pressing 
one  of  the  four  SELECT  buttons.  The  changes  are 
applied  instantly  to  the  audio  when  the  up/down 
keys  are  pressed  so  the  user  can  check  the  volume 
level while adjusting it. 

The  last  item  on  the  volume  menu  list  is  “All”  by 
selecting  this  item  the  user  can  change  the  volume 
setting  for  all  the  outputs  simultaneously.  The 
outputs are all set to the value selected in this menu 
item. 

Pressing  the  MENU  button  leaves  the  volume 
menu. This brings back the Set-up menu. 

Headphone setup menu 

The  Headphone  setup  menu  gives  access  to  the 
headphone settings. 

 

 

 

 

The  “Headphone  monitoring”  entry  indicates  the 
analogue  output  from  which  the  audio  for  the 
headphones  are  taken.  It  is  altered  by  selecting  it 
and using the up/down keys. Range is A..H. 

Headphone  volume  adjusts  the  level  of  the 
headphone  monitoring  output  (this  attenuation  is 
applied to the channel output which is already under 
volume  control).  Range  is  0dB  ..  –62dB  (Off  is 
mute) in steps of 1 dB. It is selected and altered in 
the same way as the “Headphone monitoring” entry. 

Communication status menu 

By  pressing  the  key  next  to  the  Communication 
Status item the user is taken to the Communication 
status menu: 

 

 

 

From this menu the user can view the error status of 
the unit and reset the error counters. The error status 

-Out A (12POL): -12 dB 

 

-Out B (13ALB): +15 dB 
-Out C ( 2ENG):   0 dB 
-Out D ( 5DAN):  +7 dB 

   

-Out A: 12Polish       

 

-Out B: 13Albanian 
-Out C:  2English 
-Out D:  5Danish       

   

-Headphone monitoring: A 
-Headphone volume: -20dB   
 

 Rx Errors:           0 
 Tx Retries:          0 
 Tx Dropped:          0 
-Reset counters 

-Out A: 12Polish       

 

-Out B: 13Albanian 
-Out C:  2English 
>Out D:  5Danish       

   

Содержание DCS 600

Страница 1: ...DCS 6000 User Manual Danish Interpretation Systems DIS Digital Conference System AO 6008 Audio Output Unit with firmware 5 3 5 or later...

Страница 2: ...pretation Systems User Manual Copyright 2007 DIS AO6008 REV M DOC 16 01 2007 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from th...

Страница 3: ...6000 system 5 Features 5 System components 6 Central equipment etc 6 Interpreter equipment 6 Voting equipment 6 Conference equipment and channel selectors 6 Operating instructions 7 AO 6008 Audio Outp...

Страница 4: ...ions You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment Installation precautions Do not install the unit in a...

Страница 5: ...reened CAT5 or CAT5e cabling FTP or STP ensuring a very cost effective installation and easy set up of portable systems Firmware in Delegate units Interpreter Units Central Units etc upgradeable throu...

Страница 6: ...portable DM 6060P Conference Unit portable with one built in channel selector CM DM 6070P Conference Unit portable with two built in channel selectors CM DM 6090P Conference Unit portable with two bu...

Страница 7: ...e 8 decoded channels are available on 8 analogue outputs XLR connectors A number of AO 6008 can be combined to decode more channels Up to 20 pieces AO 6008 can be connected and configured in one syste...

Страница 8: ...placed on the left hand side of the display Each button is associated with a line pointing towards a text line in the display This indicates that pushing the button selects the functionality Enter bu...

Страница 9: ...lying transformer balanced audio signal from each of the 8 channels The outputs can be used for tape recording purpose i e or for connecting a digital infrared transmitter like DT6008 DT 6032 or analo...

Страница 10: ...ed so the user can check the volume level while adjusting it The last item on the volume menu list is All by selecting this item the user can change the volume setting for all the outputs simultaneous...

Страница 11: ...user presses ENTER the settings of the unit are replaced by the settings stored in the clipboard The settings stored in the clipboard are Channel settings for all 8 outputs Volume settings for all 8 o...

Страница 12: ...e lock status is being saved in the CU 6010 and retransmitted to the unit after power up Normal operation Normal Operation Display In normal operation the user must be able to check the language setti...

Страница 13: ...th in one chain is 200 m without repeater This includes interconnection cables between the units The max usable cable length depends on the units connected and length of feeding cables etc Maximum cab...

Страница 14: ...recorders for recording the interpreted channels or to IT6008 Infrared Transmitter s for transmitting the interpreted channels wireless Using AO 6008 with IT 6108 IR Transmitter When using the AO 6008...

Страница 15: ...the DT 60xx Infrared Transmitter the audio output level on the AO 6008 has to be set to match the sensitivity on the transmitter The correct level to be set on each connected channel on the AO 6008 is...

Страница 16: ...follows Pair 1 Pin 1 2 Pair 2 Pin 3 6 Pair 3 Pin 4 5 Pair 4 Pin 7 8 The phase of the pairs must be correct and the wiring spec as stated in CAT5 EIA 568 B have to be followed Note CAT6 cables can norm...

Страница 17: ...er manual Connectors DCS LAN network 2 pieces RJ45 Analogue outputs connectors 8 XLR3 male connectors Remote Control commands in out By using SW 6000 the user can control the AO 6008 through the CU 60...

Страница 18: ...Danish Interpretation Systems User Manual Manual 01 18 04440 18...

Отзывы: