24. 

Setup System 

No. of Cameras 

Select the number of cameras connected (1 to 4) 

Max. NOM to Overview 

Select the number of microphones which can be opened 

before the system switches to the overview picture (1 to 8) 

Overview delay (sec) 

Adjusting the delay before switching to the overview picture 

(0-10 sec) 

Tracking ON/OFF 

When set to OFF the cameras will not move bases on 

opening of the microphones. Default is ON  

Change DIS connection 

Brings the screen, where the connection mode can be 

changed. 
Use the icon in the top left corner to return to the Main Menu 

 

Содержание CCS 7800

Страница 1: ...CCS 7800 Installation Manual Danish Interpretation Systems DIS Camera Control System CP 7801 Camera Control Package Version 1 5 User Manual ...

Страница 2: ...stems Installation Manual Copyright 2007 2010 DIS CP 7801 USER MANUAL REV H DOC 14 08 2013 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher ...

Страница 3: ...atic 6 Setting up the system 6 Using the iPod Control 8 Main Menu 9 Instant Camera Control 9 Camera Presets Setup 10 Setup System 11 Save Recall Layouts 11 After the system is setup 11 Use with CU 60xx direct connection 12 Schematic 12 Setting up the system 12 Using the iPod Control 13 Main Menu 13 Instant Camera Control 14 Camera Presets Setup 15 Setup System 16 Assign Seats 17 Save Recall Layout...

Страница 4: ...on ISS 506 Seamless Switcher and Extron MSW Mini Switcher Series The iPod Touch Interface is used for programming and store camera presets into the camera system controller When using multiple cameras multiple presets can be stored for each seat The System Control Unit stores the presets for the camera and controls the camera movement as well as controlling an optional video switcher The System co...

Страница 5: ...t RS 232 CU 2 m Adapter Adapter RS 232 F RS232 F ECA Important It is important that the settings in the iPod IPC Settings CF iViewer are not changed If changed the DIS Camera Control software might be deleted in the iPod and the iPod has to be send to factory for upload of new software The Adapter RS 232 F RS232 F ECA which are used when CP 7851 Camera Control Package is connected to ECA applicati...

Страница 6: ...in above schematic Single Camera ECA connection using the cables supplied The RS 232 connector on the PC running the ECA shall be connected to COM1 on the SCU using the RS 232 cable plus the RS232 adapter NOTE that the adaptor has to be mounted in the PC end of the RS 232 cable The Visca cable from the Camera shall be connected to COM 2 on the SCU 2 Change the SW 6000 ECA settings Baud Rate 9600 ...

Страница 7: ...tallation Manual Manual 01 19 78010 7 3 Insert command line parameter in the SW 6000 CUI shortcut ALLMICOFF 4 Start the SW 6000 applications CUA CUI and ECA 5 Turn on power to the Wireless Router the Camera Controller and the Camera s ...

Страница 8: ...9 78010 8 Using the iPod Control 6 Turn on power to the iPod and select Wi Fi 7 Choose the DIS CP 7801 xxx network The Linksys has to be powered up and connected to the Camera Control Unit 8 Start CF iViewer on the iPod Touch the screen to Start 9 Select ECA Mode ...

Страница 9: ...tem Save Recall Layouts 11 Instant Camera Control The Instant Camera Control is used for operating the cameras manual if desired Select which camera to operate using the four camera buttons The camera can now be operated using the arrow buttons for UP Down and Left Right movement The speed of the movement as well as Zoom In Out can be adjusted Use the icon in the top left corner to return to the M...

Страница 10: ...rophone and repeat the steps 3 6 for the next microphone 8 Continue step 3 6 for all microphones seats 9 Turn off all microphones 10 Select Save Preset 400 shall now be saved for camera 1 preset 400 is the preset for the overview position 11 Go to Room Layouts and save the layout Instead of switching microphones on off as described above the seat can also be selected using the keypad on the Select...

Страница 11: ...e connection mode can be changed Use the icon in the top left corner to return to the Main Menu 14 Save Recall Layouts When camera presets has been made the layout can be stored in the Camera System Control Unit Up to three layouts can be saved The Save button saves the current preset to the selected Layout x into a file on the Camera System Control Unit The Recall button recalls the selected Layo...

Страница 12: ... as shown in above schematic Single Camera CU 6005 11 connection using the cables supplied The RS 232 connector on the CU 6005 11 shall be connected to COM1 on the SCU using the RS 232 cable The Visca cable from the Camera shall be connected to COM 2 on the SCU 16 On the CU 60xx do the following setting Set Baud Rate 19200 using the controls and LCD display on the front plate of the central unit S...

Страница 13: ... DIS CP 7801 xxx network The Linksys has to be powered up and connected to the Camera Control Unit 20 Start CF iViewer on the iPod Touch the screen to begin and select Direct CU Mode 21 Main Menu The Main Menu window will be shown and consist of the following menus Instant Camera Control Camera Presets Setup Setup System Assign Seats Save Recall Layouts ...

Страница 14: ... used for operating the cameras manual if desired Select which camera to operate using the four camera buttons The camera can now be operated using the arrow buttons for UP Down and Left Right movement The speed of the movement as well as Zoom In Out can be adjusted Use the icon in the top left corner to return to the Main Menu ...

Страница 15: ...same seat if desired 8 Turn of the microphone and repeat the steps 4 7 for the next microphone 9 Continue step 4 7 for all microphones seats 10 Turn off all microphones 11 Select Save Preset 400 shall now be saved for camera 1 preset 400 is the preset for the overview position 12 Go to Room Layouts and save the layout Instead of switching microphones on off as described above the seat can also be ...

Страница 16: ...n be opened before the system switches to the overview picture 1 to 8 Overview delay sec Adjusting the delay before switching to the overview picture 0 10 sec Tracking ON OFF When set to OFF the cameras will not move bases on opening of the microphones Default is ON Change DIS connection Brings the screen where the connection mode can be changed Use the icon in the top left corner to return to the...

Страница 17: ...n seats 1 Select Seat Setup is OFF Push to turn ON 2 Select yes to Clear existing Seat data and reassign all seats 3 Activate a microphone The number of the microphone is shown Together with the text Seat Unassigned 4 Select Enter Seat number 5 Type in the seat number to be used for this microphone and select 6 Assign Seat number 7 Turn of the microphone 8 Repeat step 3 7 for all microphones 9 Sel...

Страница 18: ...turn to the Main Menu 27 Save Recall Layouts When camera presets has been made the layout can be stored in the Camera System Control Unit Up to three layouts can be saved The Save button saves the current preset to the selected Layout x into a file on the Camera System Control Unit The Recall button recalls the selected Layout x and overwrites the current presets Use the icon in the top left corne...

Страница 19: ...o switcher using contact closure control can be used Up to four cameras can be connected to the System Control Unit SCU The Sony EVI Cameras operate in a daisy chain configuration the first unit in the chain will have Identity no 1 the second unit will have Identity no 2 and so on Extron MSW Mini Switcher Series The switcher is controlled with contact closure control The Contact connector on the M...

Страница 20: ...anish Interpretation Systems Installation Manual Manual 01 19 78010 20 Extron ISS 506 Seamless Switcher This switcher is connected using LAN connection The Switcher has to be set to use IP 192 168 10 111 ...

Страница 21: ...o the Wireless Router using one of the four LAN ports and turn on power to the Linksys 29 Open Internet Explorer and type http 192 168 10 1 Login leave empty Password admin This will open a login screen on the Router 30 Select Wireless page and change Change to another Wireless Channel Press Save Settings in the button on the screen 31 Reboot the Linksys ...

Страница 22: ...anish Interpretation Systems Installation Manual Manual 01 19 78010 22 VISCA Control Cables configuration with Sony cameras Below is VISCA cables configuration for both RS 422 and RS 232 for Sony cameras ...

Страница 23: ...ECA mode 1 Check Baud rate setting on the ECA application 2 Check that the RS 232 Adaptor is mounted in the PC end of RS 232 cable 3 Check RS 232 cable from SCU to ECA The link icon in the Assign Seats menu does shown no connection to the CU 1 Check RS 232 cable from SCU to CU 60xx 2 Check Baud rate setting on the CU 60xx 19200 Baud The iPod will not connect to the Wireless Router or the connectio...

Отзывы: