10 |
DANGEROUS MUSIC
Benefit: Normal: With the button de-selected (dim light) the AD+ will send out sync via all digital outputs including Word Clock.
External: Selecting this button (bright LED) will make the AD+ slave to an external word clock source. For example, if
utilizing a master studio clock, this would distribute WC to the AD+. The
SAMPLE RATE
LEDs will cycle through until
the
LOCK LIGHT
turns from Red to Green indicating that sync has been achieved.
Master: Depress the button for 5 seconds. The LED will blink. Now the AD+ is the master studio clock, outputting Word
Clock and other digital sources will slave to it.
Note:
When in Master clock mode, the sample rate must be manually selected and the destination devices must be set to the
identical sample rate (i.e. all units at 192kHz).
Tip:
,
Try utilizing the CONVERT-AD+ as the master clock. Our high profile beta testers found it “remarkably revealing &
detailed” and “...this is the best sounding clock auditioned to date- and we’ve tried everything.”
Footnote: The CONVERT-AD+ leverages JetPLL technology and surrounds it with analog genius, thus executing it flawlessly.
(JetPLL, JET and Jitter Elimination Technology are trademarks of TC Applied Technologies Ltd. JET is patented
technology used under sublicense from TC Applied Technologies, & is the intellectual property of Sonopsis Ltd. blah,
blah, blah INGSOC corporate speak...)
18. USB AUTO DETECT
[REAR PANEL USB OUTPUT CONNECTOR PICTURED ABOVE]
Feature: Compatible with Apple and PC. CoreAudio in OS X and ASIO in Windows.
Benefit: Connect the CONVERT-AD+ to any USB 2.0 or above compliant computer to receive output of the AD+. Apple is
driverless and built into the OS X. For PC you must download the driver from www.dangerousmusic.com.
Feature: Automatic USB Sample Rate Detection
Benefit: Open a session and the sample rate will be selected automatically. This is especially useful when the CONVERT-AD+
is part of an aggregate device group with CONVERT-2 or CONVERT-8 D/As, thus allowing users to create a system
that will function like a singular, virtual interface.
Operation:
ON
- The selected sample rate LED will blink slowly, the other LEDs will all light solid, and sample rate selection from
the front panel will be locked out.
OFF-
The selected sample rate LED only will remain lit. Sample rate selection changes can be executed from the
front panel manually.
Note: By default, the CONVERT-AD+ ships with this feature ON. To turn this feature OFF: press and hold the sample rate
SELECT button for three seconds. To re-enable the automatic mode, plug in a valid USB connection to CoreAudio
(Mac) or ASIO (Windows) and hold the sample rate SELECT button for three seconds.
Note: This mode is only available in internal word clock mode (i.e. WORD CLOCK button is dimly lit). This mode will be
overidden if the CONVERT-AD+ is clocked from the word clock input (brightly lit WORD CLOCK button) or used as
the word clock master (blinking WORD CLOCK button).