Problem—what to do
Problem
What to do
WS unit does not work properly.
•
Check the power supply via the CAN connector.
•
Check if the CAN baud rate is set correctly.
•
Check if the wiring is correct (connector pinning)
•
Check if the CAN network is terminated correctly:
measuring 60 Ohms between CAN-H and CAN-L and at
least one termination resistor in a desk network.
•
Check if the device is configured correctly.