Bit
Hex
Dec
Extended status word
(
16-94 Ext. Status Word
)
0
00000001
1
Ramping
1
00000002
2
AMA running
2
00000004
4
Start CW/CCW
3
00000008
8
Slow down
4
00000010
16
Catch up
5
00000020
32
Feedback high
6
00000040
64
Feedback low
7
00000080
128
Output current high
8
00000100
256
Output current low
9
00000200
512
Output freq hgh
10
00000400
1024
Output freq low
11
00000800
2048
Brake check OK
12
00001000
4096
Braking max
13
00002000
8192
Braking
14
00004000
16384
Out of speed range
15
00008000
32768
OVC active
16
00010000
65536
AC brake
17
00020000
131072
Password timelock
18
00040000
262144
Password protection
19
00080000
524288
20
00100000
1048576
21
00200000
2097152
22
00400000
4194304
Unused
23
00800000
8388608
Unused
24
01000000
16777216
Unused
25
02000000
33554432
Unused
26
04000000
67108864
Unused
27
08000000
134217728
Unused
28
10000000
268435456
Unused
29
20000000
536870912
Unused
30
40000000
1073741824
Unused
31
80000000
2147483648
Unused
Table 8.15 Extended Status Word
Bit (Hex)
Unit
diagnose
bit
PROFIBUS warning word
(
9-53 Profibus Warning Word
)
00000001
160
Connection with DP-master is not OK.
00000002
161
Unused
00000004
162
FDL (fieldbus data link layer) is not OK.
00000008
163
Clear data command received.
00000010
164
Actual value is not updated.
00000020
165
Baudrate search
00000040
166
PROFIBUS ASIC is not transmitting
00000080
167
Initialising of PROFIBUS is not OK.
00000100
152
Drive is tripped.
00000200
153
Internal CAN error
00000400
154
Wrong configuration data from PLC
00000800
155
Wrong ID sent by PLC.
00001000
156
Internal error occurred.
00002000
157
Not configured
00004000
158
Timeout active
00008000
159
Warning 34 active
Table 8.16
9-53 Profibus Warning Word
Bit (Hex)
Comm. option STW (
16-84 Comm. Option STW
)
00000001
Parameterisation OK
00000002
Configuration OK
00000004
Clear mode active
00000008
Baudrate search
00000010
Waiting for parameterisation
00000020
Waiting for configuration
00000040
In data exchange
00000080
Not used
00000100
Not used
00000200
Not used
00000400
Not used
00000800
MCL2/1 connected
00001000
MCL2/2 connected
00002000
MCL2/3 connected
00004000
Data transport active
00008000
Unused
Table 8.17
16-84 Comm. Option STW
NOTICE
16-84 Comm. Option STW
is not part of extended
diagnosis.
Read out the alarm words, warning words and extended
status words via serial bus or optional fieldbus for
diagnosis.
8.4 Fault Messages via DP Diagnosis
The standard DP function features an on-line diagnosis,
which is active during DP initialisation as well as data
exchange mode.
Troubleshooting
Programming Guide
MG37G102
Danfoss A/S © Rev. 05/2014 All rights reserved.
53