11.2.11 Power Terminal Mounting Plate
To remove or reinstall the power terminal mounting plate, use the following steps. Refer to
and
.
Disassembly
1.
Remove the motor terminal block. Refer to
chapter 11.2.9 Motor Terminal Block
.
2.
Remove 5 thread-forming screws (T25) from the
power terminal mounting plate.
3.
Remove 3 nuts (8 mm) from the bottom of the
power terminal mounting plate.
4.
Remove the power terminal mounting plate from
the unit.
Reassembly
Tighten fasteners according to
.
1.
Position the power terminal mounting plate in
the unit.
2.
Secure 5 thread-forming screws (T25) in the
power terminal mounting plate.
3.
Fasten 3 nuts (8 mm) at the bottom of the plate.
4.
Replace the motor terminal block. Refer to
chapter 11.2.9 Motor Terminal Block
D2h/D4h/D7h/D8h/J9 Unit Dis...
VLT
®
FC Series, D1h–D8h, Da2/Db2/Da4/Db4, E1h–E4h, J8/J9
200
Danfoss A/S © 02/2019 All rights reserved.
MG94A502
11
11
Содержание VLT FC Series
Страница 2: ......