2 Product Overview
2.1 Introduction
The product overview applies to both FCP 106 and FCM
106.
VLT
®
DriveMotor FCP 106
The delivery comprises frequency converter only. A wall
adapter plate or motor adapter plate is also required for
installation. Order the adapter plate separately.
195NA447.10
Illustration 2.1 FCP 106
VLT
®
DriveMotor FCM 106
The frequency converter is mounted onto the motor upon
delivery. The combined FCM 106 and motor from Danfoss
is known as the DriveMotor.
195NA419.10
Illustration 2.2 FCM 106
2.1.1 Gasket
Mounting of FCP 106 onto a motor requires fitting a
customised gasket. The gasket fits between the motor
adapter plate and the motor.
No gasket is supplied with the FCP 106 frequency
converter.
Therefore, before installation, design and test a gasket to
fulfil the ingress protection requirement (for example IP55,
IP66 or Type 4X).
Requirements for gasket:
•
Maintain the ground connection between
frequency converter and motor. The frequency
converter is grounded to the motor adapter
plate. Use a wire connection between motor and
frequency converter, or ensure metallic contact
between the motor adapter plate, and motor.
•
Use a UL approved material for the gasket, when
UL listing or recognition is required for the
assembled product.