Prior to removing cables from the AC contactors, note the
mounting orientation of the AC contactors and connection
of all cables for proper reinstallation.
1.
Remove the five nuts (0.39 in [10 mm]) the AC
interconnect bus assembly and remove the
cabling from each side of the AC contactor.
Remove the AC interconnect bus assembly.
2.
Disconnect the coil wires from terminals A1 and
A2 by loosening the retaining screws (not
shown).
3.
Disconnect the wires from the auxiliary contactors
by loosening the retaining screw.
4.
Remove the AC contactor by removing the four
mounting nuts (0.39 in [10 mm]).
Reinstall in the reverse order of this procedure. See
for torque tightening values.
8.2.9 Common Mode (CM) RFI Filter Card
1.
Disconnect the cables from MK1, MK5, MK6, and
MK7.
2.
Remove the common mode RFI filter card by
removing the four screws (T-25) from the
standoffs.
Reinstall in the reverse order of this procedure. See
for torque tightening values.
8.2.10 Differential Mode (DM) RFI Filter
Card
1.
Disconnect the cables from MK105, MK106, and
MK107
2.
Remove the differential mode RFI filter card by
removing the four screws (T-25) from the
standoffs.
Reinstall in the reverse order of this procedure. See
for torque tightening values.
8.2.11 MOVs
1.
Disconnect the wires from the terminals on the
top and bottom of the MOV by loosening the
retaining screws.
2.
Remove the MOV by removing the two screws
(T-20) top and bottom.
Reinstall in the reverse order of this procedure. See
for torque tightening values.
8.2.12 Discharge Card
1.
Disconnect MK100 from the discharge card.
2.
Remove the discharge card by removing the four
screws (T-25).
Reinstall in the reverse order of this procedure. See
for torque tightening values.
8.2.13 Soft Charge Resistor
1.
Disconnect the cable going to fuses FU14 and FU
15 and the AC contactors.
2.
Remove the soft charge resistor by removing the
4 retaining nuts (0.30 in [7 mm]).
Reinstall in the reverse order of this procedure. See
for torque tightening values.
8.3 Active Section (Bottom) Instructions
8.3.1 Input Terminal Mounting Plate
CAUTION
Two Person Lift
The input terminal mounting plate supports various
customer-ordered options. The input terminal mounting
plate with options attached can exceed 35 kg (60 lbs).
Assistance is required for removal. Failure to provide
assistance when during removal could result in personal
injury.
Note that the input terminal mounting plate provides
mounting for various options. The fused disconnect option
is shown.
1.
Disconnect the line power input wiring from
terminals L1, L2, L3 and the ground connector.
2.
Remove the 3 cross bus bars between the input
terminals and the input inductor. (These are
located above the optional RFI filter if the RFI
filter is present.) Remove three nuts (0.67 in [17
mm]) (not shown), three (T-40) screws, and (0.51
in [13 mm]) nuts from the passive side of the
unit.
3.
Remove input terminal mounting plate by
removing eight (0.39 in [10 mm]) retaining nuts
from plate.
E-Frame Sizes Disassembly a...
VLT Advanced Active Filter AAF006 D and E Frames Service Manual
8-10
MG90Z122 - VLT
®
is a registered Danfoss trademark
8