104
3..
Inputs and Outputs
#
#
#
#
#
Parameter
Parameter
Parameter
Parameter
Parameter
Factory Setting
Factory Setting
Factory Setting
Factory Setting
Factory Setting
Range
Range
Range
Range
Range
Changes
Changes
Changes
Changes
Changes
4-Setup
4-Setup
4-Setup
4-Setup
4-Setup
Conversion
Conversion
Conversion
Conversion
Conversion
Data
Data
Data
Data
Data
Description
Description
Description
Description
Description
During Operation
During Operation
During Operation
During Operation
During Operation
Index
Index
Index
Index
Index
T
T
T
T
Type
ype
ype
ype
ype
300 T
T
T
T
Terminal 16 Digital Input
erminal 16 Digital Input
erminal 16 Digital Input
erminal 16 Digital Input
erminal 16 Digital Input
RESET
Yes
Yes
0
5
301 T
T
T
T
Terminal 17 Digital Input
erminal 17 Digital Input
erminal 17 Digital Input
erminal 17 Digital Input
erminal 17 Digital Input
NO OPERATION
Yes
Yes
0
5
302 T
T
T
T
Terminal 18 Digital Input
erminal 18 Digital Input
erminal 18 Digital Input
erminal 18 Digital Input
erminal 18 Digital Input
START
Yes
Yes
0
5
303 T
T
T
T
Terminal 19 Digital Input
erminal 19 Digital Input
erminal 19 Digital Input
erminal 19 Digital Input
erminal 19 Digital Input
REVERSING
Yes
Yes
0
5
304 T
T
T
T
Terminal 27 Digital Input
erminal 27 Digital Input
erminal 27 Digital Input
erminal 27 Digital Input
erminal 27 Digital Input
SAFETY INTERLOCK
Yes
Yes
0
5
305 T
T
T
T
Terminal 29 Digital Input
erminal 29 Digital Input
erminal 29 Digital Input
erminal 29 Digital Input
erminal 29 Digital Input
JOG
Yes
Yes
0
5
306 T
T
T
T
Terminal 32 Digital Input
erminal 32 Digital Input
erminal 32 Digital Input
erminal 32 Digital Input
erminal 32 Digital Input
NO OPERATION
Yes
Yes
0
5
307 T
T
T
T
Terminal 33 Digital Input
erminal 33 Digital Input
erminal 33 Digital Input
erminal 33 Digital Input
erminal 33 Digital Input
NO OPERATION
Yes
Yes
0
5
308 T
T
T
T
Terminal 53, Analog
erminal 53, Analog
erminal 53, Analog
erminal 53, Analog
erminal 53, Analog
NO OPERATION
Yes
Yes
0
5
IIIIInput
nput
nput
nput
nput Voltage
Voltage
Voltage
Voltage
Voltage
309 T
T
T
T
Terminal 53, Min. Scaling
erminal 53, Min. Scaling
erminal 53, Min. Scaling
erminal 53, Min. Scaling
erminal 53, Min. Scaling
0.0 V
0.0 - 10.0 V
Yes
Yes
-1
5
310 T
T
T
T
Terminal 53, Max. Scaling
erminal 53, Max. Scaling
erminal 53, Max. Scaling
erminal 53, Max. Scaling
erminal 53, Max. Scaling
10.0 V
0.0 - 10.0 V
Yes
Yes
-1
5
311 T
T
T
T
Terminal 54, Analog
erminal 54, Analog
erminal 54, Analog
erminal 54, Analog
erminal 54, Analog
NO OPERATION
Yes
Yes
0
5
IIIIInput
nput
nput
nput
nput Voltage
Voltage
Voltage
Voltage
Voltage
312 T
T
T
T
Terminal 54, Min. Scaling
erminal 54, Min. Scaling
erminal 54, Min. Scaling
erminal 54, Min. Scaling
erminal 54, Min. Scaling
0.0 V
0.0 - 10.0 V
Yes
Yes
-1
5
313 T
T
T
T
Terminal 54, Max. Scaling
erminal 54, Max. Scaling
erminal 54, Max. Scaling
erminal 54, Max. Scaling
erminal 54, Max. Scaling
10.0 V
0.0 - 10.0 V
Yes
Yes
-1
5
314 T
T
T
T
Terminal 60, Analog Input
erminal 60, Analog Input
erminal 60, Analog Input
erminal 60, Analog Input
erminal 60, Analog Input
REFERENCE
Yes
Yes
0
5
Current
Current
Current
Current
Current
315 T
T
T
T
Terminal 60, Min. Scaling
erminal 60, Min. Scaling
erminal 60, Min. Scaling
erminal 60, Min. Scaling
erminal 60, Min. Scaling
4.0 mA
0.0 - 20.0 mA
Yes
Yes
-4
5
316 T
T
T
T
Terminal 60, Max. Scaling
erminal 60, Max. Scaling
erminal 60, Max. Scaling
erminal 60, Max. Scaling
erminal 60, Max. Scaling
20.0 mA
0.0 - 20.0 mA
Yes
Yes
-4
5
317 Live Zer
Live Zer
Live Zer
Live Zer
Live Zero T
o T
o T
o T
o Time
ime
ime
ime
ime
10 sec.
1 - 99 sec.
Yes
Yes
0
5
318 Function After T
Function After T
Function After T
Function After T
Function After Time Out
ime Out
ime Out
ime Out
ime Out
NO FUNCTION
Yes
Yes
0
5
319 T
T
T
T
Terminal 42, Output
erminal 42, Output
erminal 42, Output
erminal 42, Output
erminal 42, Output
MOTOR CURRENT
4 - 20 mA
Yes
Yes
0
5
320 T
T
T
T
Terminal 42, Output,
erminal 42, Output,
erminal 42, Output,
erminal 42, Output,
erminal 42, Output,
5000 Hz
1 - 32000 Hz
Yes
Yes
0
6
Pulse Scaling
Pulse Scaling
Pulse Scaling
Pulse Scaling
Pulse Scaling
321 T
T
T
T
Terminal 45, Output
erminal 45, Output
erminal 45, Output
erminal 45, Output
erminal 45, Output
OUT. FREQ.
4 - 20 mA
Yes
Yes
0
5
322 T
T
T
T
Terminal 45, Output,
erminal 45, Output,
erminal 45, Output,
erminal 45, Output,
erminal 45, Output,
5000 Hz
1 - 32000 Hz
Yes
Yes
0
6
Pulse Scaling
Pulse Scaling
Pulse Scaling
Pulse Scaling
Pulse Scaling
323 Relay 1, Output Function
Relay 1, Output Function
Relay 1, Output Function
Relay 1, Output Function
Relay 1, Output Function
NO ALARM
Yes
Yes
0
5
324 Relay 01, ON Delay
Relay 01, ON Delay
Relay 01, ON Delay
Relay 01, ON Delay
Relay 01, ON Delay
0 sec.
0 - 600 sec.
Yes
Yes
0
6
325 Relay 01, OFF Delay
Relay 01, OFF Delay
Relay 01, OFF Delay
Relay 01, OFF Delay
Relay 01, OFF Delay
2 sec.
0 - 600 sec.
Yes
Yes
0
6
326 Relay 2, Output Function
Relay 2, Output Function
Relay 2, Output Function
Relay 2, Output Function
Relay 2, Output Function
RUNNING
Yes
Yes
0
5
327 Pulse Reference,
Pulse Reference,
Pulse Reference,
Pulse Reference,
Pulse Reference,
5000 Hz
Depends on
Yes
Yes
0
6
Max. Frequency
Max. Frequency
Max. Frequency
Max. Frequency
Max. Frequency
input terminal
328 Pulse Feedback, Max. Freq.
Pulse Feedback, Max. Freq.
Pulse Feedback, Max. Freq.
Pulse Feedback, Max. Freq.
Pulse Feedback, Max. Freq.
25000 Hz
0 - 65000 Hz
Yes
Yes
0
6