Table 6 - Thru-Drive Pump Housing Torque Specs
INLET HOUSING
THRU-DRIVE ADAPTOR (SAE A & SAE B)
THRU-DRIVE ADAPTOR (SAE C)
ISO (NM)
SAE (ft
•
lb)
ISO (NM)
SAE (ft
•
lb)
ISO (NM)
SAE (ft
•
lb)
Dry
Oiled
Dry
Oiled
Dry
Oiled
Dry
Oiled
Dry
Oiled
Dry
Oiled
VMQ125T
153+/-16 115+/-12 113+/-11 85+/-9 —
—
—
—
—
—
—
VMQ135T
305+/-31 229+/-23 225+/-23 169+/-17 153+/-16
115+/-12 113+/-11 85+/-9
305+/-31 229+/-23 225+/-23 169+/-17
VMQ145T
305+/-31 229+/-23 225+/-23 169+/-17 153+/-16
115+/-12 113+/-11 85+/-9
305+/-31 229+/-23 225+/-23 169+/-17