3.2 Option Board OPTBM
1
2
3
4
5
6
9 10 11 12 13 14
7
8
V GND +
- +
- +
-
+
- +
- +
-
X5
X6
X3
X4
e3
0b
i4
11
.1
0
Illustration 6: The Terminals X5 and X6 of the Digital Pulse Type Encoder Interface Board
1
Configurable encoder voltage.
2
GND.
3
A+. Terminal A of digital pulse signal.
4
A-. Terminal A of digital pulse signal.
5
B+. Terminal B of digital pulse signal.
6
B-. Terminal B of digital pulse signal.
7
Z+. Reference signal, optional.
8
Z-. Reference signal, optional.
9
A+. Unmodified encoder signal loopback.
10
A-. Unmodified encoder signal loopback.
11
B+. Unmodified encoder signal loopback.
12
B-. Unmodified encoder signal loopback.
13
Z+. Unmodified encoder signal loopback.
14
Z-. Unmodified encoder signal loopback.
The OPTBM option board is similar to the OPTBL option board, but in addition, the OPTBM option board has a digital pulse TTL/HTL
type encoder interface board attached to it.