background image

Code Num-
ber

Filter type code

Manufacturer part
code

Rated
voltage
[V DC]

Cooling Nominal

current
at 50 °C
[A]

Power
loss at
20 °C
[W]

Protec-
tion
rating

Switching
frequency
[kHz]

181B5959

LDC-0030-6-0-ATr 56606-SET-THER-

MIK

181B5960

LDC-0050-6-0-APt 36326-SET-PT100

1025

AN

50

250

IP00

5

181B5961

LDC-0050-6-0-ATr 36326-SET-THER-

MIK

181B5962

LDC-0092-5-0-APt 36327-SET-PT100

750

AN

92

340

IP00

5

181B5963

LDC-0092-5-0-ATr 36327-SET-THER-

MIK

181B5966

LDC-0092-6-0-APt 56771-SET-PT100

1025

AN

92

330

IP00

5

181B5967

LDC-0092-6-0-ATr 56771-SET-THER-

MIK

181B5964

LDC-0092-5-0-BPt 36584-SET-PT100

750

AF

92

300

IP00

5

181B5965

LDC-0092-5-0-BTr 36584-SET-THER-

MIK

181B5970

LDC-0170-6-0-APt 37404-SET-PT100

1025

AN

170

450

IP00

5

181B5971

LDC-0170-6-0-ATr 37404-SET-THER-

MIK

181B5972

LDC-0270-5-0-APt 38739-SET-PT100

750

AN

270

460

IP00

5

181B5973

LDC-0270-5-0-ATr 38739-SET-THER-

MIK

181B5976

LDC-0400-6-0-APt 38331-SET-PT100

1025

AN

400

840

IP00

5

181B5977

LDC-0400-6-0-ATr 38331-SET-THER-

MIK

181B5978

LDC-0400-6-0-BPt 38349-SET-PT100

1025

AF

400

1100

IP00

5

181B5979

LDC-0400-6-0-BTr 38349-SET-THER-

MIK

181B5980

LDC-0420-5-0-APt 39023-SET-PT100

750

AN

420

750

IP00

5

181B5981

LDC-0420-5-0-ATr 39023-SET-THER-

MIK

181B5982

LDC-0540-6-0-BPt 44079-SET-PT100

1025

AF

540

1300

IP00

5

181B5983

LDC-0540-6-0-BTr 44079-SET-THER-

MIK

181B5986

LDC-0900-5-0-BPt 53552-SET-PT100

750

AF

900

1900

IP00

5

181B5987

LDC-0900-5-0-BTr 53552-SET-THER-

MIK

AJ377845348678en-000101 / 172F4785 | 19

Danfoss A/S © 2023.01

Specifications

DC Filters

Design Guide

Содержание Vacon NXP

Страница 1: ...Design Guide DC Filters VACON NXP DC DC Converter drives danfoss com...

Страница 2: ......

Страница 3: ...ing 7 DC Filter Types 7 Selection 9 Selecting the DC Filter 9 DC Filter Selection Air cooling 9 DC Filter Selection Liquid cooling 11 Installation Guidelines 13 Cabling 13 Thermal Protection 13 Mounti...

Страница 4: ...nd options The VACON NXP DC DC Converter operating guide provides information about the installation and operation of the VACON NXP DC DC Converter application The VACON NXP DC DC Converter applicatio...

Страница 5: ...dous situation which if not avoided will result in death or serious injury W A R N I N G Indicates a hazardous situation which if not avoided could result in death or serious injury C A U T I O N Indi...

Страница 6: ...for lifting purposes C A U T I O N BURN HAZARD FROM HOT SURFACES The filter surface turns hot during operation Wait for the filter to cool down before touching it N O T I C E DAMAGE FROM LOOSE CONNEC...

Страница 7: ...be as high as 1100 V that is 1150 V D input and 50 V DC output Due to the high voltage difference a high inductance value is required to guarantee proper functionality in all operation points The DC f...

Страница 8: ...tion rating 0 IP00 2 IP21 5 IP54 A Cooling method A Natural convection B Forced air cooling C Liquid cooling Pt Temperature measurement type Pt Pt100 temperature sensor Tr Thermal relay X Reserved for...

Страница 9: ...age max current fs 5 kHz Iout nominal A Filter selection Iout max A Filter selection FR4 NXI_0004 5 4 8 LDC 0010 6 0 Axx 8 LDC 0010 6 0 Axx NXI_0009 5 10 18 NXI_0012 5 13 4 24 FR6 NXI_0016 18 LDC 0010...

Страница 10: ...DC fs 5 kHz Low Voltage max current fs 5 kHz Iout nominal A Filter selection Iout max A Filter selection FR6 NXI_0010 6 11 1 LDC 0010 6 0 Axx 14 6 LDC 0010 6 0 Axx NXI_0013 6 14 6 19 NXI_0018 6 20 3...

Страница 11: ...ble 5 DC Filter Selection for Liquid cooled 500 V Drives According to Energy Storage Requirements Drive enclosure size Drive type High Voltage 750 V DC fs 5 kHz Low Voltage max current fs 5 kHz Iout n...

Страница 12: ...ut nominal A Filter selection Iout max A Filter selection CH61 NXP_0170 6 199 LDC 0160 6 0 Cxx 340 LDC 0160 6 0 Cxx NXP_0208 6 244 416 NXP_0261 6 309 500 CH62 NXP_0325 6 385 650 LDC 0340 6 0 Cxx NXP_0...

Страница 13: ...re at the top of the 1 phase inductors and are marked as shown in Illustration 3 10 30 A inductors have terminal connectors 50 1150 A inductors have busbar terminals DC filter terminal sizes and mount...

Страница 14: ...lt signal connected to terminals 3 and 4 1 2 3 4 e30bj645 10 Illustration 5 Terminals for Thermal Protection 5 3 Mounting The DC filter is typically mounted inside a cabinet next to the DC DC converte...

Страница 15: ...ra air baffles and fan In the filter range above 50 A the cooling arrangement must be implemented The cabinet cooling must be guaranteed also with liquid cooled DC filters Typically 30 40 of the power...

Страница 16: ...of the cabinet with care Do not use liquids for the cleaning Tightening torques Check that the tightening torques of the cable connections are according to the specifications See 7 6 Terminal and Torq...

Страница 17: ...2 Environmental Data Table 8 Environmental Data for the DC Filters Item Specification Temperature during operation 10 50 C full performance 50 60 C limited performance Current derating of 2 for each...

Страница 18: ...ctions Following the drive system connections Cooling system materials Stainless steel AISI304 AISI316 Aluminum Corrosion resistant Glycol tolerant plastics Not allowed Copper brass PVC 7 4 Technical...

Страница 19: ...LDC 0170 6 0 APt 37404 SET PT100 1025 AN 170 450 IP00 5 181B5971 LDC 0170 6 0 ATr 37404 SET THER MIK 181B5972 LDC 0270 5 0 APt 38739 SET PT100 750 AN 270 460 IP00 5 181B5973 LDC 0270 5 0 ATr 38739 SE...

Страница 20: ...1150 6 0 CTr 36859 SET THERMIK 7 5 Dimensions The dimensions in Table 13 refer to drawings shown in Illustration 7 Illustration 8 and Illustration 9 Details of the terminal connec tions can be found...

Страница 21: ...C 0420 5 0 APt 308 10 273 10 587 7 252 198 220 11x21 130 LDC 0420 5 0 APt LDC 0540 6 0 BPt 306 10 287 7 560 7 252 198 220 11x21 123 LDC 0540 6 0 BTr LDC 0900 5 0 BPt 276 10 240 5 484 5 186 210 150 11x...

Страница 22: ...tion 7 Dimensions of the Air cooled Inductors 10 30 A A E B D F G C e30bj350 10 Illustration 8 Dimensions of the Air cooled Inductors 30 A AJ377845348678en 000101 172F4785 22 Danfoss A S 2023 01 Speci...

Страница 23: ...LDC 0092 5 0 Axx Busbar 1 x D9 M8 M8 20 20 Base LDC 0092 6 0 Axx Busbar 1 x D9 M8 M8 20 20 Base LDC 0092 5 0 Bxx Busbar 1 x D9 M8 M8 20 20 Base LDC 0170 6 0 Axx Busbar 1 x D11 M10 M10 40 40 Base LDC...

Страница 24: ...l Grounding Terminal Grounding LDC 0340 6 0 Cxx Busbar D 13x20 M12 M10 70 40 Base LDC 0700 6 0 Cxx Busbar D 13x20 M12 M10 70 40 Base LDC 1150 6 0 Cxx Busbar D 13x20 M12 M10 70 40 Base AJ377845348678en...

Страница 25: ...lter types 7 L Liquid cooling 18 M Maintenance 16 Mounting 14 O Overview 7 P Purpose of the manual 4 R Recycling 16 S Safety 5 Selection 9 Specifications 17 Symbols 5 T Technical data 18 Terminals 23...

Страница 26: ...ures and other printed material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subseq...

Отзывы: