TRAVELMATE-DZ
Instruction Manual
15 |
P a g e
7.
Error Codes
Code
Reason / Solution
ERR1
Thermistor is unplugged
-
Contact Evakool
ERR2
Thermistor is short circuited
-
Contact Evakool
E1
Low Voltage
-
Please check the source voltage to ensure it is above
the cut out. Try lowering the voltage cut out setting to
LOW.
-
The vehicle cabling may be inadequate/unsuitable,
please refer to cable specifications table for correct
cable thickness (Page 2)
-
Try on a different power source
E2
Fan issue
-
Fan is drawing too many Amps (Over 1 Amp) –
Contact Evakool
E3
Compressor Start Issues
-
Unplug for 10 Minutes
-
Try on a different power source.
-
Possible Electronic Box or compressor fault – contact
Evakool
E4
The compressor speed is too low
-
Unplug for 10 Minutes
-
Reduce product load inside unit
-
Move unit to a lower ambient temperature
-
Clean vents / ensure clear air flow over compressor
E5
Ambient Temperature too high
-
Clean vents / ensure clear air flow
-
Fan Fault – Contact Evakool