Home Mode

 selects the home comfort 

temperature typically when the home is 

occupied during the day. The required 

temperatures for Home mode are selectable 

in the Temperature setting (see User Menu 

> Temperatures.) A separate Home AM and 

Home PM temperature can be chosen and 

these are automatically set according to the 

time of the day.

Note: When in Home mode if the home button 
is pressed again a 1, 2 or 3 hour heating boost 
is selected and the current home period is 
extended by the chosen time period.  The 
chosen boost period is displayed under the 
Home icon on the display.

Away

Away Mode 

selects the away comfort 

temperature typically when the home is 

unoccupied during the day. The required 

temperature for Away mode is selectable in 

the Temperature setting (see User Menu > 

Temperatures).

Asleep

Asleep Mode

 selects the nightime comfort 

temperature which is set between the end 

of the last home period of the day and the 

beginning of the first home period of the 

following day. The required temperature for 

Asleep mode is selectable in the Temperature 

setting (see User Menu > Temperatures).

Standby

The TPOne can be placed in 

Standby 

Mode

. While in Standby the TPOne will 

not control the heating system other than 

to protect against frost damage  (see User 

Menu > Installer Settings > Frost Protect for 

information on frost protect). Standby can 

be cancelled by pressing the Standby button 

again or by selecting another comfort mode.

Note: the standby option places the heating 
control in standby only, if Hot Water is set 
up this is not affected. To switch Hot Water 
control off see User Menu > Hot Water > Mode 

Comfort Modes

Содержание TPOne-M

Страница 1: ...Danfoss Heating TPOne M Electronic Programmable Room Thermostat including Domestic Hot Water Timer Installation Guide...

Страница 2: ...e property of the respective companies Danfoss and the Danfoss logotype are trademarks of Danfoss A S All rights reserved TPOne is an intelligent programmable heating control made easy TPOne includes...

Страница 3: ...proportional to room temperature TPI control strategy reduces mean water temperature improves room temperature control accuracy and enhances system efficiency 2 ErP 4 Product Class Specifications TPOn...

Страница 4: ...ing Thermostat or Remote Room Sensor positioning Please note This product should only be installed by a qualified electrician or competent heating installer and should be in accordance with the local...

Страница 5: ...3A at 230Vac 230Vac 50 60Hz Remote sensor inputs S1 S2 S1 S2 Remote room or limit sensor Wiring P O Window switch contact Domestic hot water optional timed output only NOTE Remote Sensor to be wired w...

Страница 6: ...d and TPOne will recall the settings you have defined The TPOne Standby Mode allows you to switch your heating off when not required although the thermostat continues to monitor the room temperature a...

Страница 7: ...temperature for Away mode is selectable in the Temperature setting see User Menu Temperatures Asleep Asleep Mode selects the nightime comfort temperature which is set between the end of the last home...

Страница 8: ...OK will be shown on the display when it can be used or is required Menu Back Press O to exit a menu option Pressing O while in a setting will result in that setting change not be accepted O will also...

Страница 9: ...et temperature the TPOne will call for heating from the connected heat source This is indicated by the Heat Calling icon Hot Water Calling Where the TPOne has been set up for control of domestic hot w...

Страница 10: ...2016 OK Set Time 24hr 10 45 OK Hot Water Setup Off OK 21 5 o 10 45 Thurs OK OK OK OK OK OK OK OK OK OK READY The setup wizard will run when power is first applied to the TPOne Once set the further ch...

Страница 11: ...mperatures AM 21 0 o OK 21 5 o 10 45 Thurs User Menu Temperatures OK OK OK OK OK OK OK OK 21 0 o Follow this routine to set required Comfort Mode temperatures Changes can be made for each mode once al...

Страница 12: ...le Days can be set individually or grouped and options for weekdays and weekend settings can be selected All day combinations can then have one two or three Home Periods selected TPOne will automatica...

Страница 13: ...Mon Tues Weds Thurs Fri Sat Sun OK OK OK OK From To 06 00 08 30 OK OK OK Home Period 2 OK From To 12 30 13 30 OK OK OK Home Period 3 OK From To 17 30 22 30 OK OK OK OK OK Select Home Periods OK 3 OK Y...

Страница 14: ...heating only this menu option will not be given The hot water heating feature can be deactived after installation see User Menu Installer Settings Hot Water Setup Click Save Click Save is an easy acce...

Страница 15: ...this guide Tempertures User set comfort temperatures heating individual comfort temperatures for Home AM Home PM Away and Asleep Home AM and Home PM temperatures will be set during the home periods c...

Страница 16: ...t required this feature can be switched off Default setting On Temperature Scale Choose between centigrade C or fahrenheit F Default setting C Language Choose menu language Default English Note if req...

Страница 17: ...nstallation to switch the domestic hot water option on off Default Set at startup Note Settings in the menu which are required for domestic hot water are only accessable if the Hot Water Setup is swit...

Страница 18: ...me the time at which you would like to be up to the required temperature The thermostat then calculates how soon before the required time the heating is turned up Optimised Start in TPOne is dynamic a...

Страница 19: ...cs after input is made closed circuit Floor Limit Sensor This allows for a thermostat limit sensor to be set typical application is floor heating If the temperature sensed by the limit sensor exceeds...

Страница 20: ...ating Once set the service interval timer can only be reset or deactivated by an installer having the correct access code Additional information on Service Interval can be found later in this guide No...

Страница 21: ...cancelled the alarm will recommence the following day at noon If the boiler is not serviced before the due date an audible warning will start each day at noon the service icon will also be displayed...

Страница 22: ...30 22 30 06 30 08 30 Weekend 07 30 09 30 11 30 13 30 16 30 22 30 1 2 3 Note Where TPOne has been set up for domestic hot water control the default schedule for hot water is the same as for heating In...

Страница 23: ...Danfoss Heating 23 AM 20 C PM 20 C 15 C 15 C TEMPERTURE DEFAULTS Default tables Continued...

Страница 24: ...isplayed where a window open switch has been fitted and the window is opened see page 19 Product Lock This will be displayed where a product lock switch has been fitted and the switch has been activat...

Страница 25: ...One will warn of Low Heat The heating system should be checked to confirm it is operating correctly Service Due Where the TPOne Service Interval timer has been set this warning will be shown when the...

Страница 26: ...is measuring outside it s operational parameters then it may indicate a problem with the external sensor or connecting cable If this warning cannot be reset then contact your service provider for advi...

Страница 27: ...Danfoss Heating 27...

Страница 28: ...Danfoss Ltd Ampthill Road Bedford MK42 9ER Tel 01234 364621 Fax 01234 219705 Email ukheating danfoss com Website www heating danfoss co uk Danfoss HS 02 2016 VIHSH102...

Отзывы: