background image

Installation Guide

Termix Water heater – PM2+P

7.3 Disposal

Disposal

This product should be dismantled and its components
sorted, if possible, in various groups before recycling

or disposal.
Always follow the local disposal regulations.

12

DEN-GT

VI.GE.O2.02 / LUK38042

Danfoss District Energy

Содержание TERMIX PM2+P

Страница 1: ...eneral 4 4 0 Mounting 5 4 1 Mounting 5 5 0 Design 6 5 1 Design 6 5 2 Schematic diagram 7 6 0 Controls 9 6 1 DHW temperature control 9 6 2 Maintenance 10 7 0 Troubleshooting 11 7 1 Troubleshooting in g...

Страница 2: ...Installation Guide Termix Water heater PM2 P 2 DEN GT VI GE O2 02 LUK38042 Danfoss District Energy...

Страница 3: ...s well as for small apartment buildings The water heater is available in two sizes either for 1 apartment or up to 4 apartments The Termix Water heater is applicable for decentralized heating systems...

Страница 4: ...ngerous circumstances interrupt all energy sources to the station if possible and seek expert help In case of discoloured or bad smelling domestic hot water close all shut off valves on the substation...

Страница 5: ...mean the primary supply Connections 1 Domestic cold water DCW 2 Domestic hot water DHW 3 District heating DH supply 4 District heating DH return Connection sizes DH G ext thread DCW DHW G ext thread D...

Страница 6: ...er heater PM2 P 5 0 Design 5 1 Design Your substation might look different than the substation shown Design description B Heat exchanger DHW 9 Strainer 73 PM2 P controller DHW 6 DEN GT VI GE O2 02 LUK...

Страница 7: ...ram shown Schematic description with PM2 P with GTU B Heat exchanger DHW 62 GTU Pressure equalizer 63 Sieve 73 PM2 P controller DHW DCW DH Supply DH Return Your substation might look different than th...

Страница 8: ...District Heating Return 5 2 1 Technical parameters Technical parameters Nominal pressure PN 10 PN 16 versions are available on enquiry Max DH supply temperature 120 C Min DCW static pressure 0 5 bar B...

Страница 9: ...setting the indicator of temperature setting moves towards red or blue dot This means that temperature setting is increased or decreased 6 1 2 Safety valve The purpose of the safety valve is to prote...

Страница 10: ...write down the meter readings Regular inspections of the substation according to this Instruction are recommended which should include Strainers Cleaning of strainers Meters Checking of all operating...

Страница 11: ...Defective or clogged non return valve Replace clean No electricity Check Wrong setting of automatic controls if any To adjust an electronic controller for DHW pls note enclosed instructions for elect...

Страница 12: ...P 7 3 Disposal Disposal This product should be dismantled and its components sorted if possible in various groups before recycling or disposal Always follow the local disposal regulations 12 DEN GT VI...

Страница 13: ...Installation Guide Termix Water heater PM2 P Danfoss District Energy VI GE O2 02 LUK38042 DEN GT 13...

Страница 14: ...Installation Guide Termix Water heater PM2 P 14 DEN GT VI GE O2 02 LUK38042 Danfoss District Energy...

Страница 15: ...of machines EMC Direct ive 2004 108 EEC EN 61000 6 2 2007 Electromagnetic compatibility Generic standard Immunity industry EN 61000 6 3 2007 Electromagnetic compatibility Generic standard Emission fo...

Страница 16: ...Installation Guide Termix Water heater PM2 P Produced by Danfoss A S 01 2012...

Отзывы: