manualshive.com logo in svg
background image

Operating Guide

Termix BL

1.0 Table of Contents

1.0 Table of Contents ............................................. 1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2.0 Functional description...................................... 3

3.0 Safety notes..................................................... 4

3.1

Safety Notes – general . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

4.0 Mounting ........................................................ 5

4.1

Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

4.2

Electrical connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

5.0 Design............................................................. 8

5.1

Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

5.2

Schematic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

5.3

Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

5.4

Schematic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

6.0 Controls .......................................................... 12

6.1

DHW temperature control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

6.2

Other. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

6.3

Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

7.0 Troubleshooting .............................................. 15

7.1

Troubleshooting in general . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

7.2

Troubleshooting DHW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

7.3

Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

8.0 Declaration...................................................... 18

8.1

Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Danfoss District Energy

VI.EH.D4.02 / LUK41570

DEN-GT

1

Содержание Termix BL

Страница 1: ...al connections 7 5 0 Design 8 5 1 Design 8 5 2 Schematic diagram 9 5 3 Design 10 5 4 Schematic diagram 11 6 0 Controls 12 6 1 DHW temperature control 12 6 2 Other 13 6 3 Maintenance 14 7 0 Troubleshoo...

Страница 2: ...Operating Guide Termix BL 2 DEN GT VI EH D4 02 LUK41570 Danfoss District Energy...

Страница 3: ...t exchangers Domestic hot water DHW The Termix BL is available for charging systems with large momentary demands for hot water or in installations with relatively low supply capacity The Termix BL cha...

Страница 4: ...rcumstances interrupt all energy sources to the station if possible and seek expert help In case of discoloured or bad smelling domestic hot water close all shut off valves on the substation inform th...

Страница 5: ...rict heating DH return 3 Hot water circulation HWC 4 Domestic hot water DHW 5 Domestic cold water DCW Connection sizes DH DCW DHW G 1 int thread HWC G int thread Dimensions mm Type 2 5 without cover H...

Страница 6: ...rior to installation all substation pipes and connections should be cleaned and rinsed Tightening Due to vibration during transport all substation connections must be checked and tightened before inst...

Страница 7: ...onnection The substation must be electrically connected so that it can be disconnected for repairs Outdoor temperature sensor Outdoor sensors should be mounted so as to avoid exposure to direct sunlig...

Страница 8: ...might look different than the substation shown Design description B Heat exchanger DHW G Electronic controller DHW 2 Single check valve 11 Domestic hot water pump 27 Actuator 30 Flow control with cont...

Страница 9: ...lve L Border of delivery 18 Thermometer 40 Immersion sensor 1 Ball valve 19 Surface sensor 43 Ball valve closed 2 Single check valve 24 Delivered loose with unit 44 Immersion sensor DHW Domestic Hot W...

Страница 10: ...ferent than the substation shown Design description B Heat exchanger DHW 13 Charging pump G Electronic controller DHW 27 Actuator 2 Single check valve 30 Flow control with control valve 11 Domestic ho...

Страница 11: ...pump 40 Immersion sensor L Border of delivery 18 Thermometer 43 Ball valve closed 1 Ball valve 19 Surface sensor 44 Immersion sensor 2 Single check valve 27 Actuator DHW Domestic Hot Water DCW Domest...

Страница 12: ...losed completely the handle is turned all the way to the top 2 One tap is opened 3 The small valve is set at the desired temperature 50 C The set point is marked and the valve is closed completely 4 S...

Страница 13: ...ed The blow off pipe outlet should be placed so that it discharges freely and it is possible to observe any dripping from the safety valve It is recommended to check the operation of safety valves at...

Страница 14: ...all temperatures such as DH supply temperature and DHW temperature Connections Checking all connections for leakages Safety valves The operation of the safety valves should be checked by turning the...

Страница 15: ...e or clogged non return valve Replace clean No electricity Check Wrong setting of automatic controls if any To adjust an electronic controller for DHW pls note enclosed instructions for electronic con...

Страница 16: ...posal Disposal This product should be dismantled and its components sorted if possible in various groups before recycling or disposal Always follow the local disposal regulations 16 DEN GT VI EH D4 02...

Страница 17: ...Operating Guide Termix BL Danfoss District Energy VI EH D4 02 LUK41570 DEN GT 17...

Страница 18: ...conformity applies Substations Category 0 with electrical equipment Unless fitted with a yellow label PED KAT 1 on the substationlabel then the following declaration of conformity applies Substations...

Страница 19: ...Operating Guide Termix BL Category 1 with electrical equipment Danfoss District Energy VI EH D4 02 LUK41570 DEN GT 19...

Страница 20: ...Operating Guide Termix BL Produced by Danfoss A S 02 2017...

Отзывы: