Sensor for SONO 3500 CT
Table 10- 2 Technical data
Description
Specification
Pipe design
2-track sensor with flanges and integrated transducers wet-calibrated
from factory
Nominal size
DN 100, 125, 150, 200, 250, 300, 350, 400, 500, 600, 700, 800, 900,
1000, 1200
Pressure rate
PN 16, PN 25, PN 40, EN 1092-1
Pipe materials
Carbon Steel EN 1.0345 / p235 GH, painted in light gray
Transducer design
Integrated version and welded onto the pipe
Transducer material
Stainless steel (AISI 316 / 1.4404) / brass (CuZn36Pb2As)
Media temperature
Remote: 2 to 200 °C (35.6 to 392 °F)
1)
1)
MID: minimum temperature 15 °C (59 °F)
Содержание SONO 3500 CT
Страница 1: ...Ultrasonic Flowmeter Operating Instructions SONO 3500 CT 07 2019 Edition ...
Страница 2: ......
Страница 8: ...Table of contents 6 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 14: ...Introduction 1 5 Further Information 12 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 38: ...Electrical connection 5 5 Sealing of SONO 3500 CT 36 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 50: ...Commissioning 6 4 Commissioning via PDM 48 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 54: ...Functions 7 4 Hardware key 52 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...
Страница 64: ...Service and maintenance 8 7 Battery disposal 62 SONO 3500 CT Operating Instructions 07 2019 VI SH P2 02 ...