background image

Coil resistance

Dual coil

A

B

C

D

Single coil 

A

B

P108 686E

© Danfoss A/S, 202

3

fi

(PWM) The PCP is designed to be controlled from a dc current source or voltage source. If a PWM signal is used, do not use a pulse

current of more than 120% of that required.

Single Coil 
Coil Resistance

A-B 23 Ω at 70° F,

A-B 29 Ω at 200° F

A-B 23 Ω at 70° F,

A-B 29 Ω at 200° F

A-B 106 Ω at 70° F,

A-B 130 Ω at 200° F

Dual Coil 
Coil Resistance

A-B 20 Ω at 70° F,

A-B 25 Ω at 200° F

C-D 16 Ω at 70° F,

C-D 20 Ω at 200° F

A-B 20 Ω at 70° F,

A-B 25 Ω at 200° F

C-D 16 Ω at 70° F,

C-D 20 Ω at 200° F

Phasing

Positive voltage to pin 
A produces a pressure 
rise at output port C1
Positive voltage to pin 
B produces a pressure 
rise at output port C2

Positive voltage to pin 
A produces a pressure 
rise at output port C1
Positive voltage to pin 
B produces a pressure 
rise at output port C2

Positive voltage to pin 
A produces a pressure 
rise at output port C1
Positive voltage to pin 
B produces a pressure 
rise at output port C2

Positive voltage to 

pin A or C produces a 

pressure rise at output 

port C1 Positive 

voltage to pin B or D 

produces a pressure 

rise at output port C2

Positive voltage to 

pin A or C produces a 

pressure rise at output 

port C1 Positive 

voltage to pin B or D 

produces a pressure 

rise at output port C2

Current/Voltage Range

up to 145 mA at 3.90 

Vdc (linear range)

up to 190 mA at 4.75 

Vdc (linear range)

4 mA at 0.50 Vdc

to 20 mA at 2.2 Vdc 

(linear range)

up to 205 mA at 4.50 

Vdc (linear range)

up to 170 mA at 4.50 

Vdc (linear range) 

Scale Factor

0.165 ± 0.013 Bar/mA

2.4 ± 0.2 psid/mA

0.079 ± 0.007 Bar/mA

1.15 ± 0.1 psid / mA

0.379 ± 0.034 Bar/mA

5.5 ± 0.5 psid / mA

0.101 ± 0.010 Bar/mA

1.47 ± 0.15 psid / mA

0.054 ± 0.006 Bar/mA

0.78 ± 0.08 psid / mA

 •

 • 

Отзывы: