Hydraulic and electric displacement controls
Removal
1. Thoroughly clean external surfaces prior to removal of control.
2. Using a 5 mm internal hex wrench, remove the six control mounting screws (M90). Remove the
control (M1) (with orifice check valve (T40) and spring (T30)) and control gasket (M11) from housing.
Discard the gasket.
C
Caution
Protect exposed surfaces and cavities from damage and foreign material.
Reassembly
1. Install a new gasket (M11). Verify the control orifice check valve and spring (T) are in their proper
position in the control.
2. Position the control on the housing. Insert the control linkage pin into the swashplate link.
Hydraulic/Electric displacement control
P106 187E
T
T30
T40
M90 (x6)
M1
M11
d
I
5 mm
16 N•m [12 lbf•ft]
3. With the control in position, move control assembly left and right to check engagement of pin in the
link. Proper engagement is indicated by an increasing resistance as the control is moved away from
center position. Non-engagement of pin is indicated by lack of spring force. In case of non-
engagement, remove control and repeat the above procedure.
Service Manual
Series 90 Pumps
Minor repair
62