10
GB - Commissioning Instructions
Thermostat (refer to page 3 for thermostat type)
Step 1.
Type A
Press & hold buttons
and +
for 3 seconds
Type B
Press & hold
LEARN
button for 3 seconds
Type C
Remove dial, press & hold
LEARN
button for 3
seconds (located under setting dial)
Do not replace knob until Learn process is complete
NOTE:
Thermostat now transmits continuously for 5 minutes.
Receiver
Step 2. RX1
Press and hold buttons
PROG and CH1
for 3 seconds
until green light fl ashes
Step 3. RX2 /
RX3 (if applicable)
Stat 1
- perform steps 1-2 for CH1
Stat 2
(RX2 & RX3)
Wait 5 mins, perform step 1, then press
PROG + CH2 on RX2/RX3
Stat 3
(RX3 only)
Wait 5 mins, perform step 1, then press
PROG + CH3 on RX3
Use only
during
programming
Receiver status
LED, fl ashes when
receiving
Emergency ‘ON’ button, press
if communication fails, turns
on heat, returns to AUTO when
communication is re-established.
Zone status
LEDs, lit when
‘ON’
C
ommissioning Instruc
tions
GB