Technical Information

Proportional Valve Group

PVG 32

powersolutions.danfoss.com

Содержание PVG 32

Страница 1: ...Technical Information Proportional Valve Group PVG 32 powersolutions danfoss com ...

Страница 2: ...omorrow design 0710 August 2015 PVPX modules description updated 0709 June 2015 Oil consumption corrected HH November 2014 Drawings adjusted in size HG May 2014 Fluid consumption change page 30 HF February 2014 Spec sheet update HE January 2014 Converted to Danfoss layout DITA CMS HD February 2006 Aug 2013 Various changes BA HC January 2005 New Edition AA Technical Information PVG 32 Proportional ...

Страница 3: ...pical applications for pressure compensated systems 18 PVPC adapter for external pilot oil supply 18 PVPC with check valve for open center PVP 18 PVPC without check valve for open or closed center PVP 19 PVMR friction detent 21 PVMF mechanical float position lock 21 PVBS main spools for flow control standard 21 PVBS main spools for flow control linear characteristic 21 PVBS main spools for pressur...

Страница 4: ...ules symbols description and code numbers PVP pump side modules 52 PVB basic modules 54 PVLA suction valve fitted in PVB 56 PVLP shock and suction valve fitted in PVB 56 PVM mechanical actuation 57 PVH hydraulic actuation 58 PVS end plate 58 PVAS assembly kit 58 PVPX electrical LS unloaded valve 58 PVPC plug for external pilot oil supply 59 Module selection chart Standard FC spools 60 Standard FC ...

Страница 5: ...s per valve group Several types of connection threads Low weight Compact design and installation PVG modules PVP pump side modules Built in pressure relief valve Pressure gauge connection Versions Open center version for systems with fixed displacement pumps Closed center version for systems with variable displacement pumps Pilot oil supply for electrical actuator built into the pump side module P...

Страница 6: ...resis PVEM proportional Medium performance PVEO ON OFF PVEH U PVES U proportional voltage control 0 10 V PVED CC Digital CAN controlled J1939 ISOBUS PVED CX Digital CAN controlled CANopen X tra safety PVEP PWM voltage controlled 11 32 V PVHC High Current actuator for PVG PVMR cover for Mechanical detent PVMF cover for Mechanical Float PVH cover for Hydraulic actuation Remote control units Electric...

Страница 7: ...ely or partially closes the connection to tank to maintain pump pressure Pump pressure is applied to the right hand side of the pressure adjustment spool 6 The pressure relief valve 1 will open should the load pressure exceed the set value diverting pump flow back to tank In a pressure compensated basic module the compensator 14 maintains a constant pressure drop across the main spool both when th...

Страница 8: ...and PVB with flow control spool In the closed center version of PVP an orifice 5 and a plug 7 have been fitted instead of the plug 4 This means that the pressure adjustment spool 6 will only open to tank when the pressure in channel P exceeds the set value of the pressure relief valve 1 In load sensing systems the load pressure is led to the pump control via the LS connection 8 In the neutral posi...

Страница 9: ...LS connection port A 6 Pressure adjustment spool 16 LS connection port B 7 Plug closed center 17 Suction valve PVLA 8 LS connection 18 Load drop check valve 9 LS signal 19 Pilot oil supply for PVE 10 Shuttle valve 20 Maximum oil flow adjustment screws for A B ports Load sensing for variable displacement pump supply The pump receives fluid directly from the reservoir through the inlet line A screen...

Страница 10: ...ommunicates demand to the pump control The pump control monitors the pressure differential between pump outlet and the LS signal and regulates servo pressure to control the swashplate angle Swashplate angle determines pump flow Actuator load determines system pressure The pump control monitors system pressure and will decrease the swashplate angle to reduce flow if system pressure reaches the pump...

Страница 11: ...alysis is a tool used in new applications as it will indicate whether there are special safety considerations to be met according to the machine directives EN 13849 Dependent on the determined levels conformity this analysis will detirmine if any extra requirements for the product design development process production process or maintenance example the complete product life cycle W Warning All bra...

Страница 12: ...g PVE Fault monitoring input signals and signals from external sensors to ensure the PLUS 1 main controllers correct function of the manlift Technical Information PVG 32 Proportional Valve Group Safety in application 12 Danfoss August 2017 520L0344 BC00000038en US0802 ...

Страница 13: ...used in system with fixed displacement pumps PVSK commonly used in crane application full flow dump PVPX LS dump to tank PVG 100 alternative LS dump or pilot supply disconnect PVPP pilot oil supply shut off External cartridge valve connecting LS pressure or main pressure to tank PVG 120 pump disconnect block for variable pumps Technical Information PVG 32 Proportional Valve Group Safety in applica...

Страница 14: ... deactivation Neutral detection Supply control signal neutral OFF Delay 1 PVE 1 PVE 2 Emergency stop Man present switch C C D B B A P301 318 A Emergency stop man present switch B PVE Fault monitoring signals C Neutral signal detection D Hydraulic deactivation System Control Logic e g PLUS 1 for signal monitoring and triggering signal for deactivation of the hydraulic system W Warning It is the res...

Страница 15: ... Memory US DI A DI B 2 4 3 Output Fault detection Delay DI Logic Memory US DI A DI B 2 4 3 Output OR Emergency Stop Man present switch P301 319 UDC2 Error US DI B Error DI A UDC2 Error US Error DI A Hydraulic deactivation System Control Logic e g PLUS 1 for signal monitoring and triggering signal for deactivation of the hydraulic system W Warning It is the responsibility of the equipment manufactu...

Страница 16: ... high pressure lockup of the pump control Most load sensing control valves include this orifice An optional internal bleed orifice is available for use with control valves that do not internally bleed the LS signal to tank Integral PC function The LS control also performs as a PC control decreasing pump flow when system pressure reaches the PC setting The pressure compensating function has priorit...

Страница 17: ...l min 1 US gal min For additional system protection install a relief valve in the pump outlet line Remote pressure compensated system characteristics Constant pressure and variable flow High or low pressure standby mode when flow is not needed System flow adjusts to meet system requirements Single pump can provide flow to multiple work functions Quick response to system flow and pressure requireme...

Страница 18: ...en flow is not needed System flow adjusts to meet system requirements Single pump can provide flow to multiple work functions Quick response to system flow and pressure requirements Typical applications for pressure compensated systems Constant force cylinders bailers compactors refuse trucks On off fan drives Drill rigs Sweepers Trenchers PVPC adapter for external pilot oil supply PVPC with check...

Страница 19: ...en or closed center PVP PVPC without check valve is used in systems where it is necessary to supply the PVG 32 valve with oil from a manually operated emergency pump without directing oil flow to the pilot oil supply oil consumption about 0 5 l min 0 13 US gal min When the main pump is working normally the oil is directed through the PVPC plug via the pressure reduction valve to the electrical act...

Страница 20: ...nsures that the oil flow from the manually operated emergency pump is used to pilot open the over center valve and lower the load The load can only be lowered using the mechanical operating lever of the PVG 32 valve Technical Information PVG 32 Proportional Valve Group Function 20 Danfoss August 2017 520L0344 BC00000038en US0802 ...

Страница 21: ...ure This is done either via the pressure adjustment spool in open center PVP fixed displacement pumps or via the pump control variable displacement pumps In this way the pump pressure will always correspond to the load pressure plus the stand by pressure of the pressure adjustment spool or the pump control This will normally give optimum and stable adjustment of the oil flow PVBS main spools for f...

Страница 22: ... control systems in certain applications with oscillations in the range of 1 2 2 Hz can cause severe instability problems while trying to control functions in an application Critical applications are usually related to functions with an important inertia torque and or functions with secondarily fitted pressure controlled components e g over center valves Examples a slewing function main lifting lo...

Страница 23: ...nnected to the port where the pilot signal to the over center valve is acting You will thus maintain a load independent lifting movement and achieve a stable but load depending lowering movement As the load pressure on slewing movements is usually steady irrespective of the crane being loaded or not it will be advantageous to use a full pressure control spool for A and B port In both cases we reco...

Страница 24: ...ll become load dependent and that the pump pressure may exceed the load pressure With all of the above in mind a pressure controlled spool will minimize oscillation and obtain a stable function that can be controlled smooth and precise PVPX electrical LS unloading valve PVPX is a solenoid LS unloading valve PVPX is fitted into the pump side module enabling a connection to be made between the LS an...

Страница 25: ...plate max 300 bar 4351 psi Intermittent pressure at max 250 000 cycles of full PVG life time cycles with PVSI end plate The maximum intermittent pressure at max 250 000 cycles stresses the need to confirm application duty cycle before proceeding with specification For further information contact Danfoss Product Application Engineering Intermittent pressure at max 250 000 cycles of full PVG life ti...

Страница 26: ...ny other position 8 5 73 3 No control lever position 2 x 6 Control lever range 19 5 Proportional control lever range 13 4 Control lever range float position 22 3 For further information about PVE please see the Technical Information PVE Series 4 for PVG 32 100 120 520L0553 PVE electrical actuation Technical data for PVEO and PVEM Supply voltage UDC rated 12 VDC 24 VDC range 11 V to 15 V 22 V to 30...

Страница 27: ... 450 s min 0 120 s 0 250 s 0 230 s Disconnected by means of neutral switch Reaction time from max spool travel to neutral position max 0 175 s 0 330 s 0 175 s rated 0 090 s 0 270 s 0 090 s min 0 065 s 0 250 s 0 065 s Constant voltage Reaction time from neutral position to max spool position max 0 700 s rated 0 450 s min 0 230 s Constant voltage Reaction time from max spool travel to neutral positi...

Страница 28: ...0 2 4 6 8 4 PVEH 157 504 10 PVES 0 Hysteresis control signal spool travel is indicated at rated voltage and f 0 02 Hz one cycle neutral full A full B neutral The following technical data are from typical test results For the hydraulic system a minetal based hydraulic oil with a viscosity of 21 mm2 s 102 SUS and a temperature of 50 C 122 F were used Pilot oil consumption for PVEA PVEH PVES PVEO and...

Страница 29: ...l temperature Inlet Recommended temperature 30 C to 60 C 86 F to 140 F Min temperature 30 C 22 F Max temperature 90 C 194 F Max coil surface temperature 155 C 311 F Ambient temperature 30 C to 60 C 22 F to 140 F Oil viscosity Operating range 12 to 75 mm2 s 65 to 347 SUS Min viscosity 4 mm2 s 39 SUS Max viscosity 460 mm2 s 2128 SUS Response time for LS pressure relief 300 ms Rated voltage 12 V 24 V...

Страница 30: ...PVE Electronics NC Solenoid valves Pilot oil supply B port Oil A port PVB PVM Neutral spring PVBS NO solenoid valves LVDT P A A detailed description of the variants is presented in PVE Series 4 for PVG 32 PVG 100 and PVG 120 Technical Information 520L0553 covers all analogue PVE PVEO PVEH PVES PVEA PVEM PVEU PVEP and the current controlled PVHC Electrohydraulic Actuator PVED CC Series 4 Technical ...

Страница 31: ... Hysteresis control signal spool travel is indicated at rated voltage and f 0 02 Hz one cycle neutral full A full B neutral The standard PVE s are proportional activated actuator except PVEO which is on off The PVE s have fault monitoring PVEU is available with PVEH and PVES hysteresis PVEP PVED CC and PVED CX are available with PVES hysteresis The values are typical test data for exact ranges see...

Страница 32: ...e Measured between fault output pin and ground Reset needed PVEO The PVEO is an on off activated actuator The PVEO has not fault monitoring Variants PVEO R with a ramp delayed actuation PVEO DI with direction indication feedback Anodized aluminum block ATEX certified Power supply 12 V 24 V Connectors AMP DIN Hirshmann Deutsch AMP version DIN Hirschmann version Deutsch version PVEO PVEO R 157 502 1...

Страница 33: ... PWM control signals for A and B direction The PVEP has hysteresis and fault monitoring like the PVES Power supply 11 32 V Connector Deutsch Deutsch version Not connected Error Us 3 2 1 4 5 6 Spool position PVES SP UDC LED PVED CC and PVED CX The CAN controlled PVE embedded microcontrollers support the same high spool controllability as the PVES and additional has high quality feedbacks safety mon...

Страница 34: ... 100 400 Hz PWM control signals The PVHC does not have neither fault monitoring nor internal closed loop control of the spool Power supply 12 V 24 V Connectors Deutsch AMP PVHC with AMP version 74 0 2 913 92 25 3 631 5 75 0 226 16 5 0 650 33 0 1 299 44 4 1 748 5 7 0 224 5 7 0 224 26 75 1 053 P301 123 PVHC with Deutsch version 74 0 2 913 92 25 3 631 26 75 1 053 33 0 1 299 44 4 1 748 5 7 0 224 5 7 0...

Страница 35: ... mA 280 560 mA 500 1000 mA PVHC current response and hysteresis 25 bar Pp 21 ctS 25 C The ideal curve is determined by the main spool neutral spring The PVHC has high hysteresis The hysteresis is affected by viscosity friction flow forces dither frequency and modulation frequency The spool position will shift when conditions are changed e g temperature change Technical Information PVG 32 Proportio...

Страница 36: ...alve is set at an oil flow of 15 l min 4 0 US gal min Setting range 30 to 350 bar 435 to 5075 psi with PVSI end plate 30 to 300 bar 435 to 4351 psi with PVS end plate Pressure relief valve characteristic Neutral by pass pressure drop characteristic open center PVB basic modules oil flow characteristics The oil flow for the individual spool depends on Technical Information PVG 32 Proportional Valve...

Страница 37: ...stics are plotted for a pump oil flow QP corresponding to the rated maximum spool oil flow QN Increasing the pump oil flow to 1 4 QN will give the same oil flow on the eighth as on the first basic module The letters AA A B etc denote spool types The characteristic below is shown for spool travel in both directions All other characteristics are shown for spool travel in one direction only Technical...

Страница 38: ...cteristics apply to supply oil flow of 130 l min 34 3 US gal min with the actuation of one basic module and the supply flow level If several basic modules are activated at the same time the characteristic depends on the load pressure of the actuated basic modules Oil flow as a function of spool travel characteristic Oil flow QA B as a function of supplied pump oil flow QP Technical Information PVG...

Страница 39: ...Characteristic for fully displaced flow control spools PVB without pressure compensation closed center PVP Set pressure difference between pump pressure and LS signal 10 bar 145 psi Technical Information PVG 32 Proportional Valve Group Technical characteristics Danfoss August 2017 520L0344 BC00000038en US0802 39 ...

Страница 40: ... Also take into consideration pressure drop from the pump to the PVG valve group e g long pipeline Oil flow characteristics for PVB at pressure drop at max main spool travel pressure drop for open spool in neutral position Load independent pressure compensated LS pressure limiting pressure compensated PVB Technical Information PVG 32 Proportional Valve Group Technical characteristics 40 Danfoss Au...

Страница 41: ... LSA B pressure limiting valve should be used PVLP shock valve characteristic PVLA suction valve characteristic Pressure build up for pressure controlled spools Max oil flow can be reduced by about 50 without limitation of maximum pressure by limiting the main spool travel from 7 mm 0 28 in to 5 5 mm 0 22 in Pressure control spool flow characteristics Size A Size B Example 1 Technical Information ...

Страница 42: ... l min 19 8 US gal min Given Max oil flow QA B 90 l min 23 8 US gal min Pressure setting PP 150 bar 2175 psi Load pressure PLSA 125 bar 1810 psi Result D spool see Pressure CS flow characteristics size D Normally a smaller spool can be chosen with pressure control It is our experience that the spool can be one size smaller than with normal flow control Technical Information PVG 32 Proportional Val...

Страница 43: ...nd 8 mm travel in direction B For more information regarding electrical actuation of float spools please see PVE series 4 Technical Information 520L0553 Pressure drop A B T at maximum spool travel within the proportional range 4 8 mm 0 19 in Spools D and E have the same opening area for forward flow and return flow Spool E can give 100 l min 26 4 US gal min pressure compensated oil flow due to a h...

Страница 44: ...Pressure drop A B T in float position Technical Information PVG 32 Proportional Valve Group Technical characteristics 44 Danfoss August 2017 520L0344 BC00000038en US0802 ...

Страница 45: ... PVG 32 fixed displ pump Example schematic of manually actuated PVG 32 fixed displacement pump Technical Information PVG 32 Proportional Valve Group Hydraulic systems Danfoss August 2017 520L0344 BC00000038en US0802 45 ...

Страница 46: ...p Example schematic of electrically actuated PVG 32 variable displacement pump electrical actuator shock valves relief valve Technical Information PVG 32 Proportional Valve Group Hydraulic systems 46 Danfoss August 2017 520L0344 BC00000038en US0802 ...

Страница 47: ...le content from exceeding an acceptable level i e an acceptable degree of contamination Maximum contamination for PVG 32 is 23 19 16 see ISO 4406 Calibration in accordance with the ACFTD method In our experience a degree of contamination of 23 19 16 can be maintained by using a filter fineness as described in the next section For more information please see the Danfoss literature Design Guidelines...

Страница 48: ...large particles Such particles can appear in the system as a result of pump damage hose fracture use of quick couplings filter damage starting up contamination etc The filter in the electrical actuator PVE protecting the solenoid valves has a mesh of 150 µm Bursting pressure drop for internal filters is 25 bar 360 psi Technical Information PVG 32 Proportional Valve Group Other operating conditions...

Страница 49: ...sure limiting valve O Tank connection G 16 mm 1 1 16 12 0 75 in deep P Pressure relief valve Q Pump connection G 14 mm 7 8 14 0 65 in deep or G 16 mm 1 1 16 12 0 75 in deep R LSA and LSB connections G 12 mm deep 9 16 18 0 5 in deep S Pp pilot pressure connection G PVB 1 2 3 4 5 6 7 8 9 10 11 12 L1 mm 82 130 178 226 274 322 370 418 466 514 562 610 in 3 23 5 12 7 01 8 90 10 79 12 68 14 57 16 46 18 3...

Страница 50: ... P V M R F 107 4 21 117 4 61 139 5 472 1 6 5 6 5 0 4 4 1 7 3 2 89 5 3 524 85 5 3 366 PVEO PVEM PVEH P V H V310141 A PVES F G 12 mm deep in 20 0 47 in deep PVM control lever positions Base with an angle of 37 5 Base with an angle of 22 5 37 5 67 5 9 7 5 1 2 7 5 15 7 5 187 5 1 9 5 19 5 V310018 A 22 5 52 5 82 5 1 1 2 5 1 4 2 5 172 5 19 5 19 5 V310014 A Technical Information PVG 32 Proportional Valve ...

Страница 51: ...depend on different factors such as salty environment large temperature changes high humidity rust can develope on the surface This will not affect the performance of the PVG valve group To prevent reduce rust development Danfoss recommend the PVG valve group to be painted Rust on the surface is not seen as a valid complaint issue neither on painted or unpainted PVG valve groups Technical Informat...

Страница 52: ...ilot oil supply for electrically actuated valves P G T G 157B5011 P 7 8 14 T 1 1 16 12 157B5211 P T G 157B5111 P T 1 1 16 12 157B5311 Open center pump side module for pumps with fixed displacement With pilot oil supply for electrically actuated valves Connection for electrical LS unloading valve PVPX not incl P G T G 157B5012 P 7 8 14 T 1 1 16 12 157B5212 P T G 157B5112 P T 1 1 16 12 157B5312 Clos...

Страница 53: ...iable displacement With pilot oil supply for electrical actuation and connection for pilot oil pressure Incl check valve P T G 157B5181 P T 1 1 16 12 LS connection 9 16 18 157B5381 Open center pump side module for pumps with fixed displacement With pilot oil supply for hydraulic actuation and connection for pilot oil pressure P T G 157B5190 P T 1 1 16 12 LS connection 9 16 18 157B5390 Closed cente...

Страница 54: ...6400 157B6430 Load drop check valve G 14 mm deep 157B6100 157B6130 7 8 14 0 65 in deep 157B6500 157B6530 Load drop check valve LSA B shuttle valve To be used with float position spools G 14 mm deep 157B6136 7 8 14 0 65 in deep 157B6536 Non damped compensator valve G 14 mm deep 157B6200 157B6230 7 8 14 0 65 in deep 157B6600 157B6630 V310411 A Without compensator valve LSA B shuttle valve G 14 mm de...

Страница 55: ...ities for shock valves A B Facilities for shock valves A B With non damped compensator valve Adjustable LSA B pressure limiting valves External LS connection port A B Also used for float position spools G 14 mm deep 157B6203 157B6233 7 8 14 0 65 in deep 157B6603 157B6633 Damped compensator valve Adjustable LSA B pressure limiting valves External LS connection port A B G 14 mm deep 157B6208 157B623...

Страница 56: ...gs bar 32 50 63 80 100 125 140 150 160 175 190 psi 460 725 914 1160 1450 1813 2031 2175 2320 2538 2755 Code no 157B 2210 2230 2240 2250 2265 2280 2300 2320 2350 2380 2400 Settings bar 210 230 240 250 265 280 300 320 350 380 400 psi 3045 3335 3480 3625 3845 4061 4351 4641 5075 5511 5801 PVLP shock and suction valve Symbol Description Shock and suction valve for port A and or B Not adjustable Lifeti...

Страница 57: ...d B Anodized 157B3184 PVMD cover for mechanical actuation Symbol Description Material Code No Anodized PVMD Cover for purely mechanically operated valve aluminium 157B0001 no aluminium 157B0009 yes cast iron 157B0021 no PVMR friction detent Symbol Description Material Code number Anodized PVMR Friction detent aluminium 157B0004 no aluminium 157B0012 yes cast iron 157B0024 PVMF mechanical float pos...

Страница 58: ...004 V310063 A LX PVSI without active elements LX connections Max intermittend LX pressure 350 bar 5075 psi G 1 4 10 mm deep BSP 157B2015 1 2 in 20 0 47 in deep SAE 157B2005 For mounting threats please see the chapter Dimensions PVAS assembly kit PVAS assembly kit Code no 157B 0 1 2 3 4 5 6 7 8 9 10 11 12 PVB s 8000 8001 8002 8003 8004 8005 8006 8007 8008 8009 8010 8061 8062 PVB PVPVM 8021 8022 802...

Страница 59: ...56 24 V 157B4258 Plug 157B5601 PVPC plug for external pilot oil supply PVPC plug for external pilot oil supply Symbol Description Code number PVP Plug without check valve for open or closed center G 1 2 12 mm deep 157B5400 1 2 in 20 0 47 in deep PVP Plug with check valve for open center G 1 2 12 mm deep 157B5600 1 2 in 20 0 47 in deep 157B5700 Technical Information PVG 32 Proportional Valve Group ...

Страница 60: ...7 02 11 4 way 3 position Closed neutral position 7005 7000 7001 7002 7003 700 4 7006 7126 7124 7123 7122 7121 7120 7125 B A T P 157 03 11 4 way 3 position Throttled open neutral position 7105 7100 7101 7102 7103 710 4 7106 3 way 3 position Closed neutral position P A 7200 7201 7202 7203 720 4 3 way 3 position Closed neutral position P B 7301 7302 7303 730 4 7424 7423 7422 7421 4 way 3 position Thr...

Страница 61: ...25 6 6 C 40 10 6 D 65 17 2 E 100 26 4 9024 9023 9022 9021 9020 9025 B A T P 157 02 11 4 way 3 position closed neutral position 9005 9000 9001 9002 9003 9004 9124 9123 9122 9121 9120 9125 B A T P 157 03 11 4 way 3 position Throttled open neutral position 9105 9100 9101 9102 9103 9104 FC spools for mechanical float position PVMF PVB is with LSA B shuttle valve Code number 157B PVB is without LSA B s...

Страница 62: ...9723 9722 9721 9720 B A T P 157 02 11 4 way 3 position closed neutral position 9700 9701 9702 9703 9704 9734 9733 9732 9731 9730 B A T P 157 03 11 4 way 3 position Throttled open neutral position 9710 9711 9712 9713 9714 FC spools with linear flow characteristic PVB is with LSA B shuttle valve Code number 157B PVB is without LSA B shuttle valve Press compensated flow l min US gal min ISO symbol Sy...

Страница 63: ... min US gal min ISO symbol Symbol Press compensated flow l min US gal min E 100 26 4 D 65 17 2 C 40 10 6 B 25 6 6 A 10 2 6 AA 5 1 3 AA 5 1 3 A 10 2 6 B 25 6 6 C 40 10 6 D 65 17 2 E 100 26 4 7033 7032 7031 7030 7035 4 way 3 position Closed neutral position PC A and B 7015 7010 7011 7012 7013 7134 7133 7132 7131 7130 7135 4 way 3 position Throttled open neutral position PC A and B 7115 7110 7111 711...

Страница 64: ...ition PC B 7452 7453 7563 7562 4 way 3 position Throttled B T neutral position PC A 7541 7542 7543 Standard PC spools hydraulic actuation PVB is with LSA B shuttle valve Code number 157B PVB is without LSA B shuttle valve Press compensated flow l min US gal min ISO symbol Symbol Press compensated flow l min US gal min E 100 26 4 D 65 17 2 C 40 10 6 B 25 6 6 A 10 2 6 AA 5 1 3 AA 5 1 3 A 10 2 6 B 25...

Страница 65: ...ves A and B G 7 8 14 UNF G 7 8 14 UNF Without compensator check valve 157B6000 157B6400 157B6030 157B6430 With check valve 157B6100 157B6500 157B6130 157B6530 With check valve and LSA B shuttle valve 157B6136 157B6536 With compensator valve 157B6200 157B6600 157B6230 157B6630 With damped compensator valve 157B6206 157B6236 With compensator valve LSA B relief valve and LSA B shuttle valve 157B6203 ...

Страница 66: ...g lb 0 4 0 9 0 8 1 8 PVAS assembly kit Code no 157B 0 1 2 3 4 5 6 7 8 9 10 11 12 PVB s 8000 8001 8002 8003 8004 8005 8006 8007 8008 8009 8010 8061 8062 PVB PVPVM 8021 8022 8023 8024 8025 8026 17B8027 8028 8029 8030 8081 8082 Weight kg lb 0 1 0 2 0 15 0 3 0 25 0 6 0 30 0 7 0 40 0 9 0 45 1 0 0 50 1 1 0 60 1 3 0 65 1 4 0 70 1 6 0 80 1 7 0 85 1 8 0 9 2 0 PVP pump side module PVP pump side module Descr...

Страница 67: ...2 V 157B4256 157B4985 24 V 157B4258 157B4986 Plug 157B5601 0 06 0 13 PVS and PVSI end plate Description BSP SAE Weight kg lb PVS without connections 157B2000 157B2020 0 5 1 1 PVS with LX connection G 1 8 3 8 24 UNF 157B2011 157B2021 PVSI without connections 157B2014 157B2004 1 7 3 6 PVSI with LX connections G 1 4 1 2 20 UNF 157B2015 157B2005 PVLP shock and anti cavitation valves Code no 157B203 2 ...

Страница 68: ...ult PVEH float A act fault 157B4332 157B4338 157B4392 PVEH DI active fault mon PVEH DI passive fault mon 157B4036 157B4037 157B4096 PVES active fault mon PVES passive fault mon 157B4832 157B4833 157B4834 157B4835 157B4892 PVMD PVMR PVMF PVH covers Description Code No Material Anodized Weight kg lb PVMD Cover for PVB 157B0001 aluminium no 0 1 0 2 157B0009 yes 157B0021 cast iron N A 0 9 2 0 PVMR Fri...

Страница 69: ...e Description Code No Weight kg lb Plug A or B 157B2002 0 04 0 09 Valve A or B 157B2001 0 05 0 10 Technical Information PVG 32 Proportional Valve Group Module selection chart Danfoss August 2017 520L0344 BC00000038en US0802 69 ...

Страница 70: ...d and option assembly The PVG 32 valve group is assembled the way the module selection chart shows if the code number for PVM is written in field a and the code number for PVMD PVE or PVH in field c The valve group is assembled so that the mechanical actuator is mounted on the opposite end of the basic module if the code number for PVM is written in field c of the order form and the code numbers f...

Страница 71: ...r 435 psi 50 725 40 580 63 914 50 720 80 1160 64 930 100 1450 80 1160 125 1813 100 1450 140 2031 112 1625 150 2175 120 1740 160 2320 130 1885 175 2838 145 2100 190 2755 160 2320 210 3045 180 2610 230 3335 200 2900 240 3480 210 3045 250 3625 220 3190 265 3843 235 3408 280 4061 250 3625 300 4351 270 3915 320 4641 290 4205 350 5075 320 4641 380 5511 350 5075 400 5801 370 5366 Technical Information PV...

Страница 72: ...PVG 32 specification sheet Technical Information PVG 32 Proportional Valve Group Order specification 72 Danfoss August 2017 520L0344 BC00000038en US0802 ...

Страница 73: ...Technical Information PVG 32 Proportional Valve Group Danfoss August 2017 520L0344 BC00000038en US0802 73 ...

Страница 74: ...Technical Information PVG 32 Proportional Valve Group 74 Danfoss August 2017 520L0344 BC00000038en US0802 ...

Страница 75: ...Technical Information PVG 32 Proportional Valve Group Danfoss August 2017 520L0344 BC00000038en US0802 75 ...

Страница 76: ...lutions ApS Nordborgvej 81 DK 6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New District Shanghai China 201206 Phone 86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues brochures ...