![Danfoss PVG 32 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/danfoss/pvg-32/pvg-32_installation-manual_507224007.webp)
© Danfoss A/S, 2015-05
520L0412
• Rev CE • May 2015
7
Option mounting
AMP-version on/off
Hirschmann-version
on/off
Function
Signal voltage (U
S
)
Neutral
U
S
(pin 1)
= 0.5 • U
DC
Q: P -> A
U
S
(pin 1) = (0.5 -> 0.75) • U
DC
Q: P -> B
U
S
(pin 1) = (0.5 -> 0.25) • U
DC
Function
Signal voltage (A or B)
A (pin 1)
B (pin 2)
Neutral
0
0
Q: P -> A
0
U
DC
Q: P -> B
U
DC
0
157-500.10
Grey connector
PVEA/PVEH/PVES
1
2
4
3
Pin no.
LED
Error
U
U
DC
S
P301 106
Black connector
Grey connector
DI-B
DI-A
PVEA-DI/PVEH-DI
1
2
4
3
Pin no.
LED
U
DC2
S
U
Error
U
DC
AMP-version
proportional
Hirschmann-version
proportional
PVEO/PVEO-R
157-502.11
DC
DC
U
U
3
1
2
Function
Signal voltage (U
S
)
Neutral
U
S
(pin 1)
= 0.5 • U
DC
Q: P -> A
U
S
(pin 1) = (0.5 -> 0.75) • U
DC
Q: P -> B
U
S
(pin 1) = (0.5 -> 0.25) • U
DC
Function
Signal voltage (A or B)
A (pin 1)
B (pin 2)
Neutral
0
0
Q: P -> A
0
U
DC
Q: P -> B
U
DC
0
Til DI udførelserne er det nødvendigt at have 2 U
DC
-tilslutninger (U
DC
og U
DC2
):
• U
DC
forsyner magnetventilerne, og
• U
DC2
forsyner elektronikken.
De to jordforbundne stikben (mærket 3) er internt forbundet.
Der kan med fordel anvendes to separate strømforsyninger
(jvf. tekniske informationer for PVE serie 4)
On DI versions two U
DC
connections (U
DC
and U
DC2
) are necessary.
• U
DC
will supply the solenoid valves
• U
DC2
will supply the electronics
The two ground pins (pin 3) are internally connected.
With advantages two separate power supplies can be used, see also Technical information for
PVE series 4.
Die DI Ausführungen fordern zwei U
DC
-Anschlüsse (U
DC
und U
DC2
):
• U
DC
versorgt die Magnetventile und
• U
DC2
versorgt die Elektronik.
De zwei Erdungsstecker (vermerkt 3) sind intern verbunden.
Es kann mit Vorteil zwei separate Stromversorgungen verwendet werden
(vgl. technische Informationen für PVE Serie 4)
Pour les versions DI deux raccordements U
DC
(U
DC
et U
DC2
) sont nécessaires.
• U
DC
alimente les électrodistributeurs
• U
DC2
alimente l’électronique
Les deux bornes masse (borne 3) sont reliées intéreurement
L’emploi de deux sources d’alimentation séparées a des avantages, voir Information
Technique pour PVE série 4