PVST with T-connection
The PVST end plate closes off the valve stack section placed between them by placing it at the end.
Furthermore, the end plate is ensuring Load Sense (LS) is relieved to tank pressure when the valve is not
operated.
The PVSI Start Plates features:
•
Integrated LS pressure relief valve to tank
•
Threaded T port
•
Optional integrated thermal orifice
PVST with T-connection
PVST with T-connection dimensions
77.4 [3.05]
110 [4.33]
110 [4.33]
95 [3.74]
16
[0.63]
32 [1.26]
PVST with T-connection schematic
T
See part number table for details on maximum pressure capacity
Technical specification for A/B-port
Max. continuous pressure
Max. intermittent pressure
Max. rated flow
380 bar [5510 psi]
420 bar [6090 psi]
65 l/min [17 US gal/min]
Technical specification
Parameter
Minimum
Recommended range
Maximum
Fluid temperature
-30°C [-22°F]
30 to 60°C [86 to 140°F]
90° [194°F]
Fluid viscosity
4 mm
2
/s [39 SUS]
12 to 75 mm
2
/s [65 to 347 SUS]
460 mm
2
/s [2128 SUS]
Fluid cleanliness
23/19/16 (according to ISO 4406)
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
When using a PVST with T-connection it is not possible to use the LS A/B fitting in the bottom of the PVG
section next to the PVST.
Part numbers for PVST with T-connection
Part number
Material
T-port
Mounting feet
Weight
157B2500
Steel
G1/2
M8
0.47 kg [1.05 lb]
157B2520
7/8–14
5/16–18
Technical Information
PVG 16 Proportional Valve Group
PVS End Plates
©
Danfoss | December 2018