PVEP control specification (continued)
Description
Type
Value
PWM
Control range
10 – 80 %
Float position control
PWM_A = PWM_B = 90 %
Frequency
100 -1000 Hz
Input voltage swing
0 UDC
Trigger point
70 % of V bat
Input Impedance
Standard pull down
5 kW
Power consumption
7 W
Error voltage
Fault
V bat
No fault
< 2 V
All connector terminals are short-circuit protected, and protected against reverse connection (and their
combinations). Connecting error pins from two or more PVE’s will cause the surveillance system to
malfunction.
PVEP operating conditions
Description
Type
Value
Pilot Pressure
Nominal
13.5 bar [196 psi]
Minimum
10.0 bar [145 psi]
Maximum
15.0 bar [218 psi]
Oil Consumption
Neutral
0.04 l/min [0.01 US gal/min]
Locked Position
0.1 l/min [0.03 US gal/min]
Actuating
0.6 l/min [0.16 US gal/min]
Storage Temperature
Ambient
-40 to +90°C [-40 to +194°F]
Operating Temperature
Ambient
-30 to +60°C [-22 to +140°F]
Oil Viscosity
Operating Range
12 – 75 cSt [65 – 347 SUS]
Minimum
4 cSt [39 SUS]
Maximum
460 cSt [2128 SUS]
Oil Cleanliness
Maximum
18/16/13 (according to ISO 4406)
PVEP LED characteristics
Green
Operating
Red
Internal fault
Red @ 1.5 Hz
External or float fault
Service and Parts Manual
PVG 16/32/128/256
Installation
©
Danfoss | October 2018
AX284661889190en-000101 | 31
Содержание PVG 16 PVH/Covers
Страница 1: ...Service and Parts Manual Proportional Valve Group PVG 16 32 128 256 www danfoss com...
Страница 141: ...Service and Parts Manual PVG 16 32 128 256 Danfoss October 2018 AX284661889190en 000101 141...
Страница 142: ...Service and Parts Manual PVG 16 32 128 256 142 Danfoss October 2018 AX284661889190en 000101...
Страница 143: ...Service and Parts Manual PVG 16 32 128 256 Danfoss October 2018 AX284661889190en 000101 143...