Description
Value
Maximum tank pressure
Port T Static
25 bar [363 psi]
Port T Dynamic
30 bar [435 psi]
Temperature range
Ambient
-30°C to 80°C [-22 to 176°F]
Medium
-20°C to 80°C [-4 to 176°F]
Oil viscosity
Range
12 to 75 mm2/s [65 to 347 SUS]
Minimum
4 mm2/s [39 SUS]
Maximum
400 mm2/s [2130 SUS]
Enclosure – Protection class
DEUTSCH DT
IP 67
AMP JPT
IP 66
Filtering in the hydraulic system;
Max. permissible degree of
contamination
23/19/16 (ISO 4406, 1999 version)
*
Designed to be used with hydraulic activated spools
The PVHC is produced in an environment using mineral based hydraulic oil.
Service and Parts Manual
PVG 16/32/128/256
Installation
©
Danfoss | October 2018