Technical Information
Output Configurations for PLUS+1® Controllers
520L0922
• Rev EA • Sep 2013
8
Option 3 – push/pull configuration for dual coil
You may also use two outputs to drive a bidirectional dual coil valve such as a dual coil EDC when
wired as shown below. This configuration will allow you to check the resistance of the coils for more
accurate diagnostics. Setting PinConfig = 4 on both outputs will give closed loop current control.
Refererence
FMEA Considerations
, pages 10 and 11.
2302
Coil A
Coil B
Ground
+Batt
Logic circuits
FET
FET
Logic circuits
FET
FET
PWM Closed
Loop Current
Configuration
PWM Closed
Loop Current
Configuration
Driving a Bidirectional
Proportional Valve
(continued)
2303
Coil A
Coil B
Ground
+Batt
Logic circuits
FET
FET
Logic circuits
FET
FET
PWM Closed
Loop Current
Configuration
PWM Closed
Loop Current
Configuration