DP7XX Series PLUS+1® Mobile Machine Displays

L1315553

 • Rev DA • Dec 2013

5

Product Overview

DP7XX Series PLUS+1 Mobile Machine Displays

The DP700 is designed to perform in the most extreme mobile machine environments. 

The DP700 offers three different display options to meet your application needs for both in-cab and 

open usage. An optional Projective Capacitive touch screen that works through mud, water and with 

gloves is available. 

The latest technology with backlight provides outstanding brightness and contrast performance 

resulting in an easy-to-read screen. 

Develop your own software and layout with PLUS+1 GUIDE and the screen editor. A graphic library is 

available for fast time-to-market.

LCD Options

LCD Option

Type

Contrast Brightness  

(cd/m

2

)

Viewing Angle*

For application use

Value

Transmissive

600:1

500

60°, 60°, 70°, 70°

In-cab

Standard

Transmissive

1000:1

400

80°, 80°, 80°, 80°

In and out of cab

High-performance

Transmissive-

Enhanced View TFT

800:1

550

80°, 80°, 80°, 80°

In and out of cab

*  Viewing Angle:  Up, Down, Right, Left

GPL-License (General Public License)

The DP7XX family of products contains embedded Linux operating system software that is 

copyrighted software licensed under the GPLv2 or LGPLv2.1. As an installer of this product you will 

have your own obligations under the licensing agreements, which may include among other things 

the obligation to include a copy of these licenses or to include an offer of a physical copy of the 

source code for such software with your distributions of the equipment. You should carefully review 

the licenses to determine what your obligations and options may be for your intended use.

For further details, please reference:

http://powersolutions.danfoss.com/products/mobileElectronics/plus1guide/plus1GuideDownloads/

plu1guideservicetoolsoftwarelicense/index.htm

Programming can be done either using the PLUS+1 GUIDE (Graphical User Integrated Development 

Environment) or Linux interface.

PLUS+1 GUIDE is a complete toolbox that generates downloadable applications for all programmable 

PLUS+1 Compliant products.

A screen editor allows easy development of applications by programmers without formal

software development training. The expertise from a software engineer is not needed to

find the way around in GUIDE.

The DP700 series hardware contains the following features for the Linux interface:

 

y

The 1st stage of U-Boot boot loader is installed on the system.

 

y

 There is a recovery system for reprogramming the DP700 series Operating System utilizing the 

PLUS+1 Service Tool.

 

y

Linux Kernel v2.6 with drivers for all standard peripherals.

 

y

To give the developer the possibility to connect to Linux Shell it is enabled by default.

Содержание PLUS+1 DP7 Series

Страница 1: ...powersolutions danfoss com MAKING MODERN LIVING POSSIBLE Technical Information PLUS 1 Mobile Machine Displays DP7XX Series...

Страница 2: ...s L1315553 Rev DA Dec 2013 2 Table of Revisons Date Page Changed Rev 05 Dec 2013 5 8 14 19 LCD option table added changed Panel Mounting Kit part number DA 14 Oct 2013 Various CA 12 Jul 2013 11 14 Cor...

Страница 3: ...ng Information Model Features 7 Related Products 8 Danfoss Assembled Mating Connector Kits 8 Accessories 8 Inputs Outputs Inputs 9 Digital Analog 9 Multifunction 10 Encoder 11 Outputs 11 Digital Outpu...

Страница 4: ...ils information regarding the PLUS 1 GUIDE software tool set that is used to build PLUS 1 applications DP7XX Series PLUS 1 Mobile Machine Displays Reference Documents Literature title Literature type...

Страница 5: ...oduct you will have your own obligations under the licensing agreements which may include among other things the obligation to include a copy of these licenses or to include an offer of a physical cop...

Страница 6: ...nfoss has no responsibility for any accidents caused by incorrectly mounted or maintained equipment y y Danfoss does not assume any responsibility for Danfoss products being incorrectly applied or the...

Страница 7: ...02 02 04 01 11126326 DP720 03 02 02 02 04 01 11126327 A Model Name DP700 PLUS 1 Mobile Machine Displays DP710 DP720 B LCD Options 01 Value Transmissive 02 Standard Transmissive 03 High performance Tr...

Страница 8: ...12 pin Deutsch WM 12S 10100741 12 pin connector kit 16 to 20 AWG Deutsch DTM06 12SA 12 pin connector 10102025 12 pin connector kit 20 to 24 AWG Deutsch DTM06 12SA 12 pin connector 10100944 Connection...

Страница 9: ...5 2 Input impedance k 230 3 To 0 V Input impedance with pull down k 14 1 0 3 To 0 V Input impedance with pull up k 14 1 0 3 To 5 V Input impedance with pull up down k 7 27 0 2 To 2 5 V Normal Range M...

Страница 10: ...22 Worst case error mA 0 2 I 3 Input impedance 100 2 To 0 V Shut off current mA 54 The displays do not have a Real Time Operating System RTOS Because of this the display should not be used as the mas...

Страница 11: ...0 full speed Mbit s 12 Vbus input voltage V 4 4 Vbus input resistance k 70 Vbus 5 25 V Short circuit protection No damage V 0 36 Vbus output voltage V 4 75 5 25 Vbus output current A 0 5 Vbus short c...

Страница 12: ...og to digital A D converter CAN Shield Description Unit Minimum Maximum Typical Comment Input impedance 0 68 F 1 Analog Input 5 V Only Description Unit Minimum Maximum Comment Allowed voltage at pin V...

Страница 13: ...l Description 0 Display only 1 Display CAN0 2 Display CAN1 3 Display CAN0 1 4 CAN0 5 CAN1 6 CAN0 1 Selecting channel zero will not increase CAN traffic because of the PLUS 1 GUIDE Service Tool communi...

Страница 14: ...ic Random Access Memory FRAM FRAM has a write endurance of over 100 trillion cycles that is ideal for datalogging 2kB is available for application Vault Memory DP7XX displays have 16 MB of flash vault...

Страница 15: ...gh voltage High voltage can cause fire and or electrical shock if flammable gasses or chemicals are present can cause an explosion To protect against product damage and possible injury do not exceed p...

Страница 16: ...IEC 60068 2 2 Fogging IEC 60068 Temperature change IEC 60068 2 14 Moisture ingress IEC 60529 Sunlight radiation ISO 16750 4 Temp humidity voltage IEC 60068 2 38 Chemical Condition Rating Chemical res...

Страница 17: ...shading or mounting the display at an incline rather than the horizontal There is protective glass over the display screen Caution The protective glass will break if hit with a hard or heavy object I...

Страница 18: ...ical Information DP7XX Series PLUS 1 Mobile Machine Displays L1315553 Rev DA Dec 2013 18 Installation Dimensions DP7XX in Millimeters Inches 235 20 9 26 163 50 6 44 9 90 0 39 42 60 1 68 USB 177 80 7 0...

Страница 19: ...02 4 x 70 1 4X 6 0 25 0 24 0 01 Panel Cutout Stand Alone On Post Mount according to VESA Video Electronics Standards Association Mount Standards The VESA hole pattern for this display is 75 00 mm x 75...

Страница 20: ...P2 Video power supply C1 P2 Power supply C5 P3 USB device D C4 P3 Video signal input 2 C3 P3 Video signal input 1 C1 P3 CAN0 High C5 P4 USB device GND C4 P4 Video signal input ground C3 P4 Video signa...

Страница 21: ...inside of or close to metal machine surfaces where possible this simulates a shield which will minimize the effects of EMI RFI radiation y y Do not run wires near sharp metal corners consider running...

Страница 22: ...present can cause an explosion To protect against product damage and possible injury before doing any electrical welding on a machine disconnect all power and signal cables connected to the display 1...

Страница 23: ...Technical Information DP7XX Series PLUS 1 Mobile Machine Displays L1315553 Rev DA Dec 2013 23 Notes...

Страница 24: ...ase contact the Danfoss Power Solution representative nearest you Products we offer Bent Axis Motors Closed Circuit Axial Piston Pumps and Motors Displays Electrohydraulic Power Steering Electrohydrau...

Отзывы: