manualshive.com logo in svg
background image

When in a hospital or other health care facility, observe the restrictions on the use of cellular
communication equipment. Switch CS100 unit off, if instructed to do so by the guidelines posted in
sensitive areas.

The operation of cardiac pacemakers, other implanted medical device and hearing aids can be affected
by interference from CS100 unit's antennas placed close to the device.

If in doubt about potential danger, contact a physician or the manufacturer of the implanted medical
device to verify that it is properly shielded. Pacemaker patients are advised to keep CS100 unit and its
antennas away from the pacemaker while it is on.

Air traffic

Danger of interference caused by RF energy.

The operation of wireless appliances in an aircraft is forbidden to prevent interference with
communications systems. Failure to observe these instructions may lead to the suspension or denial of
cellular services to the offender, legal action, or both.

Switch the unit off before boarding an aircraft.

Make sure it cannot be switched on inadvertently.

Explosives

Danger of explosion.

Operation of any electrical equipment in potentially explosive atmospheres can constitute a safety
hazard.

Observe the applicable regulations and precautions when you are near explosive areas (i.e. petrol
stations, fuel depots, chemical plants or where blasting operations are in progress).

Do not mount the antenna in the close environment of fuel tanks, vessels with explosives and
insufficiently shielded electronic devices.

Antennas

Danger due to absorption of RF energy.

Mobile communication devices may pose a health risk when operated in the close proximity of persons.

Install the device with integrated antenna(s) used for the CS100 to provide a separation distance of at
least 20 cm / 8 inches from all persons.

Do not operate them in conjunction or co-locate them with any other antenna or transmitter.

Electronic equipment

Danger of interference caused by RF energy

The unit receives and transmits radio frequency energy while switched on. Interference may occur if it is
used close to TV sets, radios, computers or inadequately shielded equipment.

Follow any special regulations and always switch off the unit wherever use is forbidden, or when you
suspect that it may cause interference or danger.

Avoid property damage

W

Warning

Property damage may occur and unintended movement of machine or mechanism may cause injury to
the technician or bystanders.
Before any installation of the Control system, turn ignition lock off and disconnect the battery. Before
handling the device disconnect externally. Also, disconnect independently supplied output load circuits.

Technical Information

PLUS+1 Connect CS100 IoT Gateway — Professional Install Only

Safety information

 

©

 Danfoss | October 2020

BC299456869228en-000101 | 11

Содержание PLUS+1 Connect CS100

Страница 1: ...Technical Information PLUS 1 Connect CS100 IoT Gateway www danfoss com...

Страница 2: ...on history Table of revisions Date Changed Rev October 2020 First edition 0101 Technical Information PLUS 1 Connect CS100 IoT Gateway Professional Install Only 2 Danfoss October 2020 BC299456869228en...

Страница 3: ...lable variants functions 14 Operating modes 14 GNSS Global Navigation Satellite System 14 Wireless Solution 14 SIM card 14 Input output functions I O 14 CAN interfaces 15 Device configuration 15 CS100...

Страница 4: ...Mounting Inside mount 23 Top Mount 23 Technical Information PLUS 1 Connect CS100 IoT Gateway Professional Install Only Contents 4 Danfoss October 2020 BC299456869228en 000101...

Страница 5: ...anced knowledge in electrical engineering and fieldbus systems allowing them to estimate the risks and hazards of operating the device and to integrate it into systems with components of other manufac...

Страница 6: ...0 1 2 3 4 5 1 Mounting holes 2 Housing 3 Status LED 4 Type label 5 8 Pin DEUTSCH connector C Caution This device is not field serviceable Opening the housing will void the warranty Indicator elements...

Страница 7: ...tion of this device Never rely solely on wireless device for essential communications the CS100 is not designed for safety related applications This device is designed to be used in systems which must...

Страница 8: ...k via LTE 4G Cat M1 additionally via GSM GPRS EDGE The interfaces are suitable for use in mobile and stationary systems for industry small business area and in agricultural and forestry machinery Feat...

Страница 9: ...y with Regulation No 10 ECE Regulation No 10 Revision 3 14 08 2008 Approval No 10 R XXXXXX PTCRB This device has been certified for use on PTCRB Mobile Network Operator networks For more information s...

Страница 10: ...er This device is designed to be used in systems which must be checked for conformity with legal requirements prior to placing into operation The integrator of this device is responsible to check and...

Страница 11: ...depots chemical plants or where blasting operations are in progress Do not mount the antenna in the close environment of fuel tanks vessels with explosives and insufficiently shielded electronic devic...

Страница 12: ...nstallation of the control system The following is recommended when welding on a machine equipped with electronic components Turn the engine off Remove electronic components from the machine before an...

Страница 13: ...product and part numbers DEUTSCH mating connector bag assembly K29620 16 20 AWG Cable 1m with 8 pin DEUTSCH DTM connector 11222837 20 AWG Technical Information PLUS 1 Connect CS100 IoT Gateway Profess...

Страница 14: ...hen GNSS sync is not available the local timing accuracy is 2 seconds per day Wireless Solution CS100 interfaces transmit data available on a CAN bus via LTE Cat M1 and 2G telecommunication services B...

Страница 15: ...nsmitted and stored to the Danfoss Data Portal CS100 firmware update You can load a firmware update to the CS100 via the Danfoss PLUS 1 Connect portal The firmware update may reset the saved configura...

Страница 16: ...y above 8 pin DEUTSCH CAN power supply local MFIO The table and drawing below show the pin assignment and conductor colors of the connector The colors stated in the table below are the conductor color...

Страница 17: ...us network 2 ISO 11898 2 High Speed 2 0A B Multifunction Input Output 2 DIN AIN ResIN FreqIN CrntIN CL15 DOUT Radio Module LTE Cat M1 and 2G cellular Cat M1 Throughput UL DL Max 375 kbps Max 375 kbps...

Страница 18: ...uency input middle range Description Unit Minimum Typical Maximum Comment Range Hz 0 10000 In steps of 1 Hz Range phase and quad Hz 0 5000 In steps of 1 Hz Rising voltage threshold V 3 89 Voltage requ...

Страница 19: ...tal output Description Unit Minimum Typical Maximum Comment Output Voltage range V 0 10 3 22 3 Vin 12v 500ma Vin 24V 500ma Current mA 0 500 Each output pin capable of driving 500mA No current limiting...

Страница 20: ...ice turns on The LED light correct sequence The LED lights up green constantly during the first second The LED starts to flash Problem with connection to PLUS 1 Connect portal After connecting to powe...

Страница 21: ...the device unless temperature is between 40 C and 75 C 40 F and 167 F Do not store and or transport the device unless it is kept at a temperature between 40 C and 85 C 40 F and 185 F Disposal Observe...

Страница 22: ...20 40 90 1 61 2 X 6 3 THRU 9 30 0 37 36 0 1 42 17 5 0 69 23 0 0 1 A A Minimal panel cutout CS100 Cable Pin 1 Pin 8 Pin 5 Pin 4 5 Meter 10 mm Technical Information PLUS 1 Connect CS100 IoT Gateway Pro...

Страница 23: ...ess Provide strain relief for mating connector wires C Caution Module damage may occur Use caution when installing modules It s possible to damage the module if excessive pressure is applied during th...

Страница 24: ...nfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New Distric...