7

Model

Nominal

Cap. 60 Hz

TR

Nominal cooling 

capacity**

Btu/h

Power

input

kW

A max

(code 4)

A

Efficiency

Sound

power

dB(A)

Swept

volume

cu.in/rev

Displace-

ment

cu.ft/h

Oil

charge

oz

Net

weight *

lb

COP

W/W

E.E.R.

Btu/h /W

R-22  

single

sM084

7

24600

84 000

7.38

17

3.34

11.4

74

6.99

703

111.6

141

sM090

7.5

26400

90 000

7.82

17

3.37

11.5

75

7.35

741

111.6

143

sM100

8

27500

94 000

8.14

19

3.38

11.5

75

7.76

782

111.6

143

sM110

9

31600

107 800

9.35

20

3.38

11.5

78

8.80

886

111.6

161

sM115

9.5

33700

115 200

10.08

25

3.35

11.4

79

9.46

952

128.5

172

sM120

10

36700

125 300

10.80

29

3.40

11.6

78

10.17

1024

111.6

161

sM125

10

37000

126 400

10.99

25

3.37

11.5

79

10.17

1024

128.5

172

sM148

12

43800

149 500

13.01

32

3.37

11.5

83

12.14

1222

121.7

194

sM160

13

47700

163 000

14.22

29

3.36

11.5

84

13.22

1331

135.3

198

sM161

13

47600

162 600

14.07

32

3.39

11.5

84

13.22

1331

121.7

194

sM175

14

51100

174 300

15.27

35

3.34

11.4

82.5

14.22

1432

209.6

220

sM185

15

54300

185 400

16.22

35

3.35

11.4

82.5

15.25

1535

209.6

220

sY240

20

74100

252 700

22.10

50

3.35

11.4

84.7

21.22

2137

270.5

331

sY300

25

94500

322 500

27.50

69

3.43

11.7

85.9

26.70

2687

270.5

346

tecHnical speciFications

60 Hz data

Subject to modification without prior notification
For full data details and capacity tables refer to Online Datasheet Generator : 

www.danfoss.com/odsg

sM/sY compressors

sZ compressors

Refrigerant

R-22

R-407C

Frequency

60 Hz

60 Hz

Standard rating conditions

ARI standard conditions

-

Evaporating temperature

45 °F

45 °F (dew point)

Condensing temperature

130 °F

130 °F (dew point)

Subcooling

15 °F 

15 °F 

Superheat

20 °F

20 °F

TR = Ton of Refrigeration 
COP = Coefficient Of Performance 
EER = Energy Efficiency Ratio

Rating conditions

R-407

c

 single

sZ084

7

22500

76 900

7.06

17

3.19

10.9

74

6.99

703

111.6

141

sZ090

7.5

24400

83 300

7.63

17

3.20

10.9

77

7.35

741

111.6

143

sZ100

8

26500

90 500

8.18

19

3.24

11.0

77

7.76

782

111.6

143

sZ110

9

30100

102 800

9.29

20

3.24

11.1

81

8.80

886

111.6

161

sZ115

9.5

32800

112 000

10.22

25

3.21

10.9

81

9.46

952

128.5

172

sZ120

10

34800

118 900

10.75

29

3.24

11.1

81

10.17

1024

111.6

161

sZ125

10

34900

119 200

10.89

25

3.21

10.9

81

10.17

1024

128.5

172

sZ148

12

42600

145 400

13.35

32

3.19

10.9

83

12.14

1222

121.7

194

sZ160

13

45500

155 400

14.08

29

3.23

11.0

83

13.22

1331

135.3

198

sZ161

13

46000

156 900

14.32

32

3.21

10.9

83

13.22

1331

121.7

194

sZ175

14

48700

166 200

15.28

35

3.19

10.9

84

14.22

1432

209.6

220

sZ185

15

51800

176 800

16.43

35

3.15

10.7

84

15.25

1535

209.6

220

sZ240

20

71100

242 800

22.70

50

3.14

10.7

87

21.22

2137

270.5

331

sZ300

25

87900

300 000

27.49

69

3.20

10.9

87.5

26.70

2687

270.5

346

sZ380

30

108500 368 500

33.40

79

3.25

11.0

89.5

32.42

3263

284

348

with oil charge & accessories 

**  at nominal speed  
 

 

2900 rpm at 50 Hz 

 

 

3500 rpm at 60Hz

Содержание Performer SM Series

Страница 1: ...selection application guidelines Performer scroll compressors SM SY SZ 50 60 Hz R 22 R 407C R 134a R 404A R 507A MAKING MODERN LIVING POSSIBLE REFRIGErATION AIR CONDITIONING...

Страница 2: ...oft start controller 15 SYSTEM DESIGN RECOMMENDATIONS 17 Refrigerant charge limit and compressor protection 17 Crankcase heater 17 Liquid line solenoid valve LLSV 17 Pump down cycle 17 Suction accumul...

Страница 3: ...Compressor sound radiation 27 Mechanical vibrations 27 Gas pulsation 27 INSTALLATION 28 Compressor handling 28 Mounting 28 Removing connections shipping plugs 29 System cleanliness 29 Tubing 29 Filter...

Страница 4: ...once the power has been switched off The figure below illustrates the entire compression process Therearetwoscrollelements anorbiting scroll and a fixed scroll The center of the orbiting scroll trace...

Страница 5: ...or protection type Applies to Description For trio assemblies please contact Danfoss 5 Model SM SZ 084 090 100 110 120 148 161 SM SZ 115 125 160 175 185 SY SZ 240 300 SY SZ 380 Version V R C MA MB AA...

Страница 6: ...s and capacity tables refer to Online Datasheet Generator www danfoss com odsg SM SY compressors SZ compressors Refrigerant R 22 R 407C Frequency 50 Hz 50 Hz Standard rating conditions ARI standard co...

Страница 7: ...Online Datasheet Generator www danfoss com odsg SM SY compressors SZ compressors Refrigerant R 22 R 407C Frequency 60 Hz 60 Hz Standard rating conditions ARI standard conditions Evaporating temperatu...

Страница 8: ...re indicated by a double line The solid line represents the limit when the su perheat is 20o F or less The dotted line shows the limit when the superheat is 54o F Interpolate for superheat values betw...

Страница 9: ...110 120 130 140 150 160 10 0 10 20 30 40 50 60 Evaporating temperature F Condensing temperature F Condensing temp limits S H 20o F S H 54o F SUPERHEAT 10 0 10 20 30 40 50 60 Evaporating temperature F...

Страница 10: ...e application envelopes Dew temperature Mean temperature Example for SZ 084 to 185 Example for SZ 084 to 185 Refrigerant R 407C is a zeotropic mix ture with a temperature glide in both evaporator and...

Страница 11: ...ion 1 5 8 2 1 4 1 3 8 Discharge 1 1 8 1 3 4 7 8 SY SZ 240 Suction 1 5 8 2 1 4 1 5 8 Discharge 1 1 8 1 3 4 1 1 8 SY SZ 300 Suction 1 5 8 2 1 4 1 5 8 Discharge 1 1 8 1 3 4 1 1 8 SY SZ 380 Suction 2 1 8...

Страница 12: ...230V 3 60 Hz 460V 3 60 Hz 575V 3 60 Hz 380 3 60 Hz Voltage range 60 Hz 180 253 V 414 506V 517 632V 342 418 V Electrical connections The terminal box is provided with a 1 1 29 mm hole for the power su...

Страница 13: ...or 115 230 vac 13 ELECTRICAL CONNECTIONS AND WIRING The motor protection module is factory installed in the terminal box and has both phase sequence protection and pre wired thermistor connections The...

Страница 14: ...KS BP HP DGT TH 180 s T1 T2 M T3 KA KA A1 A2 A3 Wiring diagram without pump down cycle Suggested wiring diagrams Compressor models SM SZ 115 125 160 175 185 Wiring diagram with pump down cycle CONTRO...

Страница 15: ...starter MCI soft starters are designed to reduce the starting and stopping current of 3 phase AC motors MCI soft starters can reduce in rush current by up to 40 thereby eliminating the detrimental ef...

Страница 16: ...erated by the MCI As the contactor always switches in no load condition it can be selected on the basis of the thermal current AC 1 Contacts 13 14 are not applicable with MCI 25C When control voltage...

Страница 17: ...wind Below 23 F ambient temperature with wind speed above 11 mph however we recommend thermal insulation of crankcase heaters in order to limit the energy losses to the surrounding air Since the total...

Страница 18: ...the table a crankcase heater must be used During operation liquid floodback may be detected by measuring either the oil sump temperature which should be at least 18 F above the saturated suction tempe...

Страница 19: ...est Crankcase heater Cooling only systems with remote condensor and split system units Refrigerant migration floodback test Crankcase heater because full system charge is not definable risk of overcha...

Страница 20: ...d motor protection module in the terminal box This device provides efficient reliable protection against overheating overloading and phase loss or reversal Connected to the module are PTC sensors embe...

Страница 21: ...a single direction and the motor is wound so that if the connections are correct the rotation will also be correct Compressor models SM SZ 084 to 185 incorporate an internal reverse vent valve which w...

Страница 22: ...e motor terminals must lie within these table limits during both start up and normal operations The maximum allowable voltage imbalance is 2 Voltage imbalance causes high amperage on one or more phase...

Страница 23: ...e compressor from draining back to the discharge side of the compressor during off cycle The upper loop also helps avoid condensed liquid refrigerant from draining back to the compressor when stopped...

Страница 24: ...nsing temperature shown in the application envelopes Under very low ambient conditions in which testing has revealed that the above procedures might not ensure satisfactory condensing and suction pres...

Страница 25: ...compressor to draw vapor from on the suction side The compressor can then quickly enter into a vacuum condition it is therefore important that the expansion device be sized correctly and that a suffi...

Страница 26: ...ure switch cut outs and may place excess strain on both bearings and motor To prevent such problems it is important to allow a 3 ft minimum discharge line length between the compressor discharge port...

Страница 27: ...and code numbers Mechanical vibrations Vibration is most effectively controlled by isolation Performer scroll compressors are designed to produce minimal vibration during operation Rubber isolaters on...

Страница 28: ...erminal box with the intention of moving the compressor as the force placed upon the terminal box will cause extensive damagetoboththeboxandthemotor protection module component inside Lock washer HM 8...

Страница 29: ...nsables and system contaminants such as metal shavings solder and flux have a negativeimpactoncompressorservice life Many of these contaminants are small enough to pass through a mesh screen and can c...

Страница 30: ...age internal components Using a heat shield a heat absorbing compound or both is recommended Due to the relatively large tubing and fitting diameters used for larger scrolls a double tipped acetylene...

Страница 31: ...the table below Never use other gasses such as oxygen dry air or acetylene as these may form an inflammable mixture Pressurize the system on HP side first then LP side Leak detection compressor Use a...

Страница 32: ...ng device operation and desired superheat readings Suction and discharge pressure within acceptable levels Correct oil level in compressor sump indicating proper oil return Low foaming in sight glass...

Страница 33: ...daptator not available rotolock valve set not available Discharge 1 3 8 Solder sleeve adaptator set Rotolock valve set 33 Connectors and valves ACCESSORIES Compressor model Oil type Oil name Code no S...

Страница 34: ...mark UL SM SZ175 185 6 7773108 Belt type crankcase heater 75 W 230 V CE mark UL SM SZ175 185 6 7973005 Belt type crankcase heater 75 W 230 V CE mark UL SM SZ175 185 50 7773118 Belt type crankcase heat...

Страница 35: ...ble for code 3 version compressors Discharge gas temperature must not exceed 275 F The discharge gas thermostat acces sory kit includes all components required for installation as shown below The ther...

Страница 36: ...lock T SM175 3RM SM175 4RM SM175 7RM SM175 9RM SM185 Single Brazed T SM185 3CAM SM185 4CAM SM185 7CAM SM185 9CAM Rotolock T SM185 3RM SM185 4RM SM185 7RM SM185 9RM SY240 Single Brazed M24 SY240A3AAM S...

Страница 37: ...e Brazed T SZ125 3CAM SZ125 4CAM SZ125 7CAM SZ125 9CAM Rotolock T SZ125 3RM SZ125 4RM SZ125 7RM SZ125 9RM SZ148 Single Brazed Int SZ148 3VAM SZ148 4VAM SZ148 7VAM SZ148 9VAM SZ160 Single Brazed T SZ16...

Страница 38: ...75 185 6 48 4 37 4 33 0 1444 2 24 0 24 0 37 0 248 SY SZ 240 4 44 9 37 4 36 25 1413 2 20 1 18 3 30 7 344 SY SZ 300 4 44 9 37 4 36 25 1413 2 20 1 18 3 30 7 355 SY SZ 380 4 44 9 37 4 37 2 1440 2 20 1 18...

Страница 39: ......

Страница 40: ...n Controls for Industrial Refrigeration Industrial Automation Household Compressors Commercial Compressors Thermostats Sub Assemblies Electronic Controls Sensors We are a single source for the widest...

Отзывы: