5.12 Ensure free flow
Ensure free flow from relief valve (table 1, item
5.6, CP 8). A blocked relief valve can cause
excessive build-up of pressure and thereby cause
dangerous situations and damage to the whole
system.
5.13 Verify setting of safety/relief valves
Make sure, the relief valve is placed correctly (see
open system design, item 1).
Check the pressure settings on the name plate
of the relief valve. If they are within specifica-
tions, you can continue.
5.14 Bleed and remove air from the pump
Open bleeding plugs. Keep the plugs open until
the high-pressure pump is bleeded.
If the pump is submerged, remove all bleeding
plugs before mounting in reservoir.
5.15 Verify direction of rotation
The direction of rotation must always follow the
arrow. The arrow is placed on the pump or pump
unit.
Check the direction of rotation before mounting
the pump.
Unlock the safety circuit breaker. Start the motor
for 1 second and observe the direction of
rotation either looking on the fan of the motor or
on the coupling through the hole in the bell
housing (not available on all bell housings). If the
motor is turning the wrong direction, switch two
phases in the connection box of the motor or
reprogram the direction in VFD.
When the motor is turning in the right direction,
the pump can be mounted.
5.16 Commissioning
5.16.1 Open system
•
Check if filter element is present and
mounted correctly.
•
Switch on the circuit breaker for both
motor(s) and VFD(s).
•
Check rotation of the feed pump.
•
Start feed pump.
•
Bleed high-pressure pump until only water
leaves the high-pressure pump. Remember
to close all bleeding and draining plugs.
•
Adjust pressure relief valve to minimum
setting.
•
Check rotation of the high-pressure pump
by description in 5.15.
•
Start high-pressure pump for 2 minutes, to
make sure all air is out of the system.
•
Adjust pressure relief valve to working
pressure.
•
Check all fittings for leakage.
•
Check the temperature switch/controls. The
high-pressure pump must stop if tempera-
ture is above specified set point.
•
Check the pressure switch/controls. The
high-pressure pump must stop if pressure is
below specified set point.
•
If the system is running within the system
design limits, the system is released for
operation.
5.16.2
Closed system
(not applicable for
PAHT G 256-308)
•
Check if the reservoir is clean.
•
Check if filter element is present and
mounted correctly.
•
Fill water at the reservoir using the filling
valve. Inspect immediately for leakage.
•
Bleed high-pressure pump until only water
leaves the high-pressure pump. Remember
to close all bleeding and draining plugs.
•
Adjust pressure relief valve to minimum
setting.
•
Check rotation of the high-pressure pump
by description in 5.15.
•
Start high-pressure pump for 2 minutes, to
make sure all air is out of the system.
•
Check reservoir low level switch/controls.
The high-pressure pump must stop if low
level switch is activated.
•
Adjust pressure relief valve to working
pressure.
•
Check the temperature switch/controls.
The high-pressure pump must stop if
temperature is above specified set point.
•
Check the filter pressure switch/controls. A
warning must be given if pressure is above
specified set point.
•
If the system is running within the system
design limits, the system is released for
operation.
5.17 Check the filter condition
Evaluate contamination found in filter, replace
filter elements, if necessary.
5.18 Instruct operator and maintenance
personnel
Before using the pump/pump unit, the personnel
must be instructed in using the pump/pump
unit, its function, components, documentation
and safety.
Danfoss offers commissioning and service at
system manufacturer’s location. Rate quotes are
offered upon request.
Содержание PAHT G
Страница 16: ...16 180R9383 AQ121686503103en 000803 Danfoss 2023 03 Data sheet Product type...
Страница 36: ...36 180R9383 AQ121686503103en 000803 Danfoss 2023 03 Data sheet Product type 8 2 PAHT G 10 12 5 Data sheet...
Страница 37: ...180R9383 AQ121686503103en 000803 37 Danfoss 2023 03 Data sheet Product type 8 3 PAHT G 20 32 Data sheet...
Страница 38: ...38 180R9383 AQ121686503103en 000803 Danfoss 2023 03 Data sheet Product type 8 4 PAHT G 50 90 Data sheet...
Страница 39: ...180R9383 AQ121686503103en 000803 39 Danfoss 2023 03 Data sheet Product type 8 5 PAHT G 256 308 Data sheet...
Страница 41: ...180R9383 AQ121686503103en 000803 41 Danfoss 2023 03 Data sheet Product type Data sheet...
Страница 43: ...Danfoss 2023 03 180R9383 AQ121686503103en 000803 1 Instruction PAHT G pumps PAHT G 2 12 5 hpp danfoss com...
Страница 57: ...180R9383 AQ121686503103en 000803 57 Danfoss 2023 03 Data sheet Product type...
Страница 79: ...180R9383 AQ121686503103en 000803 79 Danfoss 2023 03 Data sheet Product type Guideline...
Страница 80: ...Danfoss DCS SGDPT SI 2023 03 80 180R9383 AQ121686503103en 000803 Data sheet Product type Guideline...