Service guide
Disassembling and assembling PAHT / PAHT G 20-32
11
180R9175 / 521B1108 / DKCFN.PI.012.E3.02 / 01.2016
3. Assembling
Lubrication:
• To prevent seizing-up, lubricate all
threads with PTFE lubrication type.
• O-rings inside pump may be lubricated
only with clean filtered water.
• O-rings for port flange, mounting flange
and flushing valve must be lubricated.
• It is important to lubricate ALL parts to
be assembled with clean filtered water
(Especially all PEEK parts).
WARNING:
Do not use silicone when assembling the
pump. Do not reuse disassembled O-rings;
they might be damaged. Always use new
O-rings.
Important:
It is essential that the pump is serviced in
conditions of absolute cleanliness. All parts
must be absolute clean before mounting.
1. Tools required for assembly of the pump.
2. Parts needed for assembly of the pump.
3. Mount 1 guide pin in housing.
4. Mount O-ring in port plate.