1 Compressor
2  Electric Expansion Valve
3  Micro Channel Heat Exchanger with axial fan
4  Refrigerant receiver with rotalock valve
5  Filter Drier
6  Sight Glass
7  Liquid Ball Valve

8  Suction Ball Valve
B1 Condensing Pressure Transducer (P1)
B2 Suction Pressure Transducer (P2)
B3  High Pressure cartridge Switch (auto-reset)(PSH)
B4 Low Pressure cartridge Switch (auto-reset) (PSL)
D1 Pressure relief valve (PRV)
R1 Ambient Temperature sensor (T4)

R2 Discharge Temperature Sensor (T2)
R3 Suction Temperature Sensor (T3)
S1  Pressure Relief Valve
R8 Discharge Temperature Sensor (T1)

 Insulation

P06 Models: OP-LPQM215-271 & OP-MPXM125-162

Instructions

118A2221A - AN363632996019en-ZA0101 | 7

© Danfoss | DCS (CC) | 2020.12

T3

T1

T4

1

3

4

5

6

7

8

P1

R1

PRV

P2

B2

B1

R3

B4

B3

R2

R1

Содержание OPTYMA Plus OP-LPQM

Страница 1: ...W Q R X Z Y Q Air in R Air out Unit W mm X mm Y mm Z mm Housing 4 Code n 114X34 or 114X44 250 900 700 700 Picture 1 Minimum mounting distances The condensing unit must only be used for its designed pu...

Страница 2: ...Handle the unit with care The packaging allows for the use of a forklift or pallet jack Use appropriate and safe lifting equipment Store and transport the unit in an upright position Store the unit be...

Страница 3: ...e Plug is not installed in unit it is replaced with adapter blanking plug Unit has liquid receiver with an Adapter Plug with 3 8 NPT connection installer end user can select various options as mention...

Страница 4: ...thermostat DI1 and put them together with an insulated 250 Vac 10mm terminal bridge Remove wire 25 room thermostat DI1 and wire 11 compressor supply and put them together with an insulated 250VAC 10mm...

Страница 5: ...l modifications in particular drilling welding broken feet and shock marks Compressor opened or returned unsealed Rust water or leak detection dye inside the compressor Use of a refrigerant or lubrica...

Страница 6: ...ish Legend A 12 Hole for Mounting B Sight Glass C Controller Display D Air in E Air out F Suction Port G Liquid Port H Nameplate Electrical Cables Note all dimension are in mm H4 Instructions 6 AN3636...

Страница 7: ...B3 High Pressure cartridge Switch auto reset PSH B4 Low Pressure cartridge Switch auto reset PSL D1 Pressure relief valve PRV R1 Ambient Temperature sensor T4 R2 Discharge Temperature Sensor T2 R3 Su...

Страница 8: ...sor R4 R5 Auxiliary Temp Sensor optional R6 Crankcase Heater R7 NTC Resistor S1 Room Thermostat optional S2 Door Limit Switch X1 Terminal Supply Supply Fan Fan Alarm Alarm Comp Compressor CCH Crankcas...

Отзывы: