User Guide
MES 1003 WMS
Doc no. 100837-MAN – Rev. E1 – Rev. date 2022-10
© Danfoss IXA A/S | Page 18
2.3.
Local Control
Local Control can be used when the system is inspected or calibrated by crew. When Local Control is enabled, the WMS
can only be started and stopped from the LCP. Local Control can be enabled using the Modbus interface or using the LCP
Local Control can only be disabled using the LCP. Local Control ensures that the sensor is not started unintentionally by
another system thus allowing crew to perform inspection and maintenance operation on the system.
When Local Control is disabled, the WMS must be started and stopped using command through the Modbus.
When Local Control is enabled, readings from the sensor can still be obtained over Modbus. The only difference is that
the system can’t be started over Modbus.
2.4.
USB Interface
The USB interface, located in the WAU inside the controller box, can be used in combination with the local control panel
and a USB drive to update the sensor software, extract a diagnostics report or download a measurement log. The USB
interface also includes the possibility to save/restore setup. The placement of the USB port can be seen in Illustration 19;
it is located behind the cover of the control box in the WAU.
The USB stick must comply with the following:
Max 16 G
1 partition only
Formatted to FAT32
Illustration 19: Placement of the USB port