background image

2

ELECTRICAL

FULL STROKE CURRENT

85

±

 11.3 mA (single coil)

42

±

 5.6 mA (series coils)

85

±

 11.3 mA (parallel coils)

See Current vs. Swashplate Angle curve

NOMINAL INPUT IMPEDANCE

24.7 ohms, .093 henries, each coil

DEADBAND

32

±

 7 psi divided by the scale factor

HYDRAULIC

FILTRATION

The system hydraulics must have 10 micron or better

filtration. The pump will contain screen filters near the

interface to the EDC at the charge port and control port

locations. The pilot will have screen filters at its input and

output control ports.

FLUID

Automatic transmission fluid or hydraulic oil, such as

Mobil DTE 24 or equivalent

OIL VISCOSITY

40-6000 SSU

OIL TEMPERATURE

-40

°

 C (-40

°

 F) minimum; 104

°

 C (220

°

 F) maximum

OPERATING SUPPLY PRESSURE

Typically 300-400 psi above case pressure

RATINGS

SCALE FACTOR

1.15 psi/mA (single coil)

2.3 psi/mA (coils in series)

1.15 psi/mA (coils in parallel)

TEMPERATURE

The valve will meet all specifications over the range of

21

°

 to  82

°

 C (70

°

 to 180

°

 F)

TECHNICAL DATA

ELECTRICAL CHARACTERISTICS

(+) Voltage to Terminal

One of Dual Coils

Dual Coils in Parallel

Dual Coils in Series

Input

Produces

Shaft

Flow Out

Rotation

Of Port

Clockwise

A or C         B or D

A or C           B or D

A                D

A                B

Counterclockwise

A or C         B or D

A or C           B or D

A                D

B                A

Start Current

14 mA with 0.43 Vdc

14 mA with 0.22 Vdc

7 mA with 0.43 Vdc

Full Stroke Current

85 mA with 2.3 Vdc

85 mA with 1.15 Vdc

42 mA with 2.3 Vdc

A

B

C

D

+

+

+

B

C

D

A

+

B

C

D

A

CURRENT VS. SWASHPLATE ANGLE

Current Vs. Swashplate Angle of the Single Coil MCV111B.

1390

15

°

10

°

5

°

100

mA

80

60

40

20

20

40

60

80

100 

mA

15

°

10

°

5

°

INPUT SHAFT ROTATION VS. TERMINAL CONNECTION VS. OUTPUT FLOW

BLN-95-8995-4

Содержание MCV111B Series

Страница 1: ...the pump s output while maintaining optimum dynamic response to control commands 1 PUMP SIZE MODEL CODE PUMP SIZE 03 30 cc 05 42 or 55 cc 07 75 cc 10 100 cc 13 130 cc Pump S N 92 19 14 130 cc Pump S N 92 19 18 25 180 or 250 cc BASE DEVICE PUMP SIZE PILOT STYLE 2 PILOT MODEL CODE PILOT STYLE 02 MS Connector 04 Packard Connector ORDERING INFORMATION The MCV111B Electrical Displacement Control is ord...

Страница 2: ...ESSURE Typically 300 400 psi above case pressure RATINGS SCALE FACTOR 1 15 psi mA single coil 2 3 psi mA coils in series 1 15 psi mA coils in parallel TEMPERATURE The valve will meet all specifications over the range of 21 to 82 C 70 to 180 F TECHNICAL DATA ELECTRICAL CHARACTERISTICS Voltage to Terminal One of Dual Coils Dual Coils in Parallel Dual Coils in Series Input Produces Shaft Flow Out Rot...

Страница 3: ...ERVO PORT FITTING X1 SAE SERVO PORT FITTING X2 MS CONNECTOR OPTION PACKARD WEATHER PACK CONNECTOR OPTION DIMENSIONS 42 cc AND 55 cc PUMP EDC LOCK NUT MANUAL OPERATOR SAE SERVO PORT FITTING X1 SAE SERVO PORT FITTING X2 CONTROL LINKAGE 10 4 0 41 22 4 0 88 27 94 1 10 52 83 2 08 203 2 8 00 8 6 REF 0 34 7 11 0 28 NEUTRAL ADJUST 7 14 DIA 6 PLACES 0 281 DIA 122 99 4 84 89 41 3 52 55 37 2 18 36 07 1 42 31...

Страница 4: ...al pressure drop when the system is at null Between the nozzle and the orifice on each side is a control port As the torque motor shifts the flapper away from one nozzle toward the other a differential control pressure results the high side being the one nearer the flapper Fluid pressure rises on this side and moves the flapper back towards null When the torque output from the motor equals the tor...

Страница 5: ... or if the pilot output pressure goes to case pressure Mechanical feedback must be present FREQUENCY RESPONSE EXCEPT FOR 130 cc PUMPS 2 Hz minimum with 052 pressure limiter orifices 3 Hz minimum without pressure limiter orifices with pressure limiters inoperative Under 500 1000 psi load at 90 phase lag with 10 mA signal at 45 mA offset TIME RESPONSE EXCEPT FOR 130 CC PUMPS 1 0 seconds 0 to full st...

Страница 6: ...nnector order part number K08106 The mating Packard ENVIRONMENTAL HUMIDITY After being placed in a controlled atmosphere of 95 humidity at 49 C 120 F for 10 days the EDC will perform within specification limits Meets MIL STD 810B WIRING connector is a bag assembly part number K03384 comprised of 1 4 14 16 gauge sleeves 2 4 18 20 gauge sleeves 3 1 plastic housing 4 4 green cable seals accept 2 2 2 ...

Страница 7: ...nsulation should just protrude beyond the seal 4 Select the larger of the two sets of pins as measured at Dimension A see the Dimension A drawing if using 14 16 gauge wire Choose the smaller if using 18 20 gauge Place the wire into the socket so that the seal edge is pushed through and extends slightly beyond the circular tabs that hold it in place Crimp in the locations shown in the Packard Conne...

Страница 8: ...hat the control orifice and spring are in the proper position in the control 2 Engage the pin on the control linkage in the mating hole in the link attached to the swashplate To ensure that linkage is engaged before adding mounting bolts simply place a finger under the electrical input connection and lightly lift If the control moves more than 3 8 inch the pin is not engaged Try again See the Cont...

Страница 9: ...e Department 3500 Annapolis Lane North Minneapolis Minnesota 55447 Phone 763 509 2084 Fax 763 559 0108 DEVICE REPAIR For devices in need of repair or evaluation include a description of the problem and what work you believe needs to be done along with your name address and telephone number RETURN TO Danfoss US Company Return Goods Department 3500 Annapolis Lane North Minneapolis Minnesota 55447 EU...

Отзывы: