Danfoss FC-300
is inserted into the EtherCAT master
system.
130BC193.11
Illustration 5.3
To function properly, each of the four process data must
be linked to variables inside the PLC. In this example, two
transmit variables and two receive variables have been
inserted in the PLC memory. To see a list of matching data
1.
Select the variable.
2.
Click the
Linked to...
button in the right window.
130BC195.12
Illustration 5.4
In the following example, the status word is linked to the
variable STW.
130BC196.11
Illustration 5.5
The status word is now linked to the variable STW in the
PLC. Remaining variables must be mapped equally to the
variables in the PLC.
130BC197.11
Illustration 5.6
After a successfully integrating the frequency converter to
the TwinCAT system, the frequency converter is now ready
for operation.
Configure the Master
MCA 124 EtherCAT Operating Instruction
14