© Danfoss | DCS (im) | 2017.07
IC.PS.P40.B3.52 | 520B7739 | 5
VOLTAGE INPUT
Max. offset
50% of selec. max. value
Cable resistance per wire (max.)
5 Ω
Sensor current
nom. 0.2 mA
Effect of sensor cable resistance (3- / 4-wire)
< 0.002 Ω / Ω
Sensor error detection
Yes
Max. offset
50% of selec. max. value
Cold junction compensation
≤ ± 1.0 °C
Sensor error detection
Yes
Sensor error current
When detecting
nom. 33 mA
Else
0 mA
TC INPUT
Type
Min. temperature
Max. temperature
Min. span
Standard
B
400 °C
1820 °C
200 °C
IEC584
E
-100 °C
1000 °C
50 °C
IEC584
J
-100 °C
1200 °C
50 °C
IEC584
K
-180 °C
1372 °C
50 °C
IEC584
L
-100 °C
900 °C
50 °C
DIN 43710
N
-180 °C
1300 °C
100 °C
IEC584
R
-50 °C
1760 °C
200 °C
IEC584
S
-50 °C
1760 °C
200 °C
IEC584
T
-200 °C
400 °C
50 °C
IEC584
U
-200 °C
600 °C
75 °C
DIN 43710
W3
0 °C
2300 °C
200 °C
ASTM E988-90
W5
0 °C
2300 °C
200 °C
ASTM E988-90
LR
-200 °C
800 °C
50 °C
GOST 3044-84
Measurement range
-12 – 800 mV
Min. span
5 mV
Max. offset
50% of selec. max. value
Input resistance
10 mΩ
OUTPUT
CURRENT OUTPUT
SENSOR ERROR DETECTION
Signal range
4 – 20 mA
Min. signal range
16 mA
Updating time
440 ms
Output signal at EEprom error
≤ 3.5 mA
Load resistance
≤ (V
supply
- 7.2) / 0.023 [Ω]
Load stability
≤ ±0.01% of span / 100 Ω
Programmable
3.5 – 23 mA
NAMUR NE43 Upscale
23 mA
NAMUR NE43 Downscale
3.5 mA
Of span =