Electrical specifications
Electrical
Sensor type
Hall Effect with redundant sensors
Resolution
Infinite
Supply voltage
Analog
5 ± 0.5 Vdc
CAN with redundant analog
outputs
9 to 60 Vdc
CAN+
9 to 60 Vdc
Output
Analog
0.5 to 4.5 Vdc
Minimum voltage
10% ± 4% Vs
Center voltage
50% ± 2% Vs
Maximum voltage
90% ± 4% Vs
CAN
2.0 B, J1939 and CANopen protocols
CAN+
2.0 B, J1939
Base maximum current
consumption
Analog
45 mA
CAN
120 mA at 9 V
CAN+
100 mA at 9 V (without LEDs or
sensor power)
Base maximum survival supply
voltage
Analog
30 Vdc
CAN
68 Vdc
CAN+
68 Vdc