background image

Product image

JS6000 Analog Output Output

Theory of operation

JS6000 joysticks are general purpose mobile machine control joysticks. They are available in a Y and an
XY axis configuration and support three grip types.

JS6000 joysticks support two electrical output options: Analog and Controller Area Network (CAN).

JS6000 joysticks support two handle position measurement technology options: Potentiometer and Hall
effect. With either option, two independent sensors per axis measure handle position. Grip analog and
switch signals are hard-wired to the joystick base.

Two PLUS+1

®

 Compliant JS6000 function blocks are available. One supports joysticks having analog

outputs and the second supports joysticks that have the CAN output option.

JS6000 joysticks with the analog output option have a number of independent direction switches that
indicate handle direction and null position. The PLUS+1

®

 Compliant JS6000 function block does not use

these switches. The 

compliant function block algorithm

 uses input voltage to determine handle position,

direction and null position.

The 

compliant function block algorithm

 uses one sensor input per axis to determine handle direction and

null position. The algorithm does not compare the dual sensor signals.

The PLUS+1

®

 Compliant function block requires that the JS6000 joystick base be supplied with 5 Vdc

regulated sensor power provided by a PLUS+1

®

 control device. JS6000 joysticks with the analog option

may be ordered with one of two output ranges: 25% to 75% of supply voltage or 10% to 90% of supply

voltage. The 

10% to 90% of supply voltage output range

 must be selected when using the PLUS+1

®

Compliant JS6000 function block.

Electrical Installation

JS6000 Analog Output

Product overview

 

©

 Danfoss | May 2017

BC00000013en-US | 0201 | 5

Содержание JS6000

Страница 1: ...Electrical Installation Joystick JS6000 Analog Output powersolutions danfoss com...

Страница 2: ...hanged Rev May 2017 Updated to Engineering Tomorrow design 0201 August 2015 Converted to Danfoss layout CA October 2006 Various BA May 2006 First edition AA Electrical Installation JS6000 Analog Outpu...

Страница 3: ...eration 5 Electrical specifications 6 Electrical installation Pinout 7 Pin location 7 Potentiometer sensor 7 Hall effect sensor 8 A series grip 8 WT WN grip 10 MG grip 11 Joystick grip and Operator Pr...

Страница 4: ...er Manual Compliant function blocks set up information 11007141 JS6000 2 axis function blocks User Manual 11007142 JS6000 3 axis function blocks User Manual 11007143 JS6000 4 axis function blocks User...

Страница 5: ...n have a number of independent direction switches that indicate handle direction and null position The PLUS 1 Compliant JS6000 function block does not use these switches The compliant function block a...

Страница 6: ...el code order character 10 2 90 2 1 5 1 6 to 2 4 RR 25 2 75 2 1 5 2 2 to 3 6 QQ 10 2 90 2 5 1 6 to 2 4 SS 25 2 75 2 5 2 2 to 3 6 TT Dual potentiometer output Minimum voltage Vs Maximum voltage Vs Swit...

Страница 7: ...nector shaft position output 8 pin connector redundant sensor output Pin Function Pin Function 1 N O signal Y axis direction switch forward 1 Second Y axis supply voltage 2 N O signal X axis direction...

Страница 8: ...e 16 pin connector Blank Pin not used Refer to JS1000 JS6000 Joystick Grips Technical Information 520L0872 for A series grip option code descriptions A series grip pinout A Series Option Code Pin numb...

Страница 9: ...0B PB3 PB2 Top switch Operator presence Common Operator presence A2L0 Switch out L Switch out L PB2 PB1 VoutL Center tap V V Common A40T PB4 PB3 PB2 PB1 Top switch Common A40D PB4 PB3 PB2 PB1 Operator...

Страница 10: ...ion 3 7 Not used 8 Not used 9 Not used 10 Not used 11 Common 12 Not used 16 pin connector WT WN grip pinout Pin Function 1 Switch position 2 2 Operator presence switch 3 Operator presence switch 4 Swi...

Страница 11: ...Not used 9 Not used 10 Not used 11 Not used 12 Common for switch 1 2 16 pin connector MG grip pinout Pin Function 1 Not used 2 Not used 3 Switch 2 4 Operator presence 5 Operator presence 6 Switch 1 7...

Страница 12: ...16 4 10 DIN AIN 3 6 1 2 8 14 15 16 4 10 DIN AIN FreqIN 3 6 4 10 AIN Temp Rheo Refer to JS1000 JS6000 Grip Technical Information 520L0872 for JS6000 base potentiometer analog output 12 pin connector P...

Страница 13: ...s list Description Quantity Ordering number Connector 1 AMP 174045 2 Terminal 20 to 22 gauge 12 AMP 175062 1 Mating connector kit 1 Danfoss 10101020 16 pin AMP connector parts list Description Quantit...

Страница 14: ...Electrical Installation JS6000 Analog Output 14 Danfoss May 2017 BC00000013en US 0201...

Страница 15: ...Electrical Installation JS6000 Analog Output Danfoss May 2017 BC00000013en US 0201 15...

Страница 16: ...er Solutions ApS Nordborgvej 81 DK 6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trad...

Отзывы: