Theory of operation
The 3-position (FNR) Electric Control uses an electric input signal to switch the pump to a full stroke
position.
Pump displacement versus electrical signal
100 %
0
100 %
Voltage Vdc
Displac
eme
nt
Hydrostatic drive line power
W
Warning
Unintended vehicle or machine movement hazard. The loss of hydrostatic drive line power, in any mode
of operation (forward, neutral, or reverse) may cause the system to lose hydrostatic braking capacity. You
must provide a braking system, redundant to the hydrostatic transmission, sufficient to stop and hold the
vehicle or machine in the event of hydrostatic drive power loss.
Hydraulic schematics
C1
C2
F00A
M14
T
P
F00B
Electrical specifications
H1 pump 3-position (FNR) electrical specifications
Voltage
12V
24V
Minimum supply voltage
9.5 Vdc
19 Vdc
Maximum supply votage
14.6 Vdc
27 Vdc
Rated power
17 W
17 W
Coil resistance at 20º C [70º F]
8.4 Ω
34.5 Ω
Electrical Installation
H1 Pump 3-Position (FNR) Electric Control
Product overview