Charge Pump Repair (removable auxiliary pad)
P106 036E
K100
K150
K500
G450
S150
S300
S250
S100
S300
S200
K200
K100
K400
10 mm
92 Nm [68 ft•lb]
K400
10 mm
92 Nm [68 ft•lb]
1. Using a 10 mm internal hex wrench, remove cap screws (K400).
2. Remove charge pump cover or auxiliary pad (K100) and gasket (K150), and discard the gasket.
Alignment pins (G450) may remain in cover or endcap.
3. Remove auxilliary pump and O-ring (K250), and discard O-ring.
4. Remove charge pump cover screws (K450) and charge pump cover (K550).
5. Remove thrust washer (K500).
Note the orientation of thrust washer. Coated side is towards charge pump coupling (K200).
6. Remove pressure-balance plate (S200) with seal (S300). Discard seal (S300).
Note orientation of valve plate and seal.
7. Remove charge pump coupling K200).
8. Remove charge pump gear set (S100) and outer ring (S150).
9. Inspect carefully the valve and pressure balance plates for wear, scratches or pits.
Scratches on these components will cause a loss of charge pressure.
If any component shows signs of wear, scratching, or pitting, replace it.
Charge Pump Repair (Integrated Auxiliary Pad)
If an auxiliary pump is attached, remove auxiliary pump and coupling before servicing charge pump.
Position pump with front shaft pointing downward. Attach securely to a proper work stand.
Service Manual
H1P 069—H1P 250 Axial Piston Single Pumps
Minor Repair
56 |
©
Danfoss | September 2020
AX152886482551en-000504