
External Filter Repair
T015
24mm
P106 035E
T150
T035
T045
1. With the prime mover off, hold the filter (T150) in place, and remove the plug (T015) using a 24 mm
wrench.
2. Remove the filter.
3. Remove and discard the seal (T045) and O-ring (T035).
4. Inspect the plug and sealing surfaces in the filter bracket.
5. Replace any damaged components.
6. Install new seal (T045) and O-ring (T035) on plug.
7. Apply hydraulic fluid to the O-ring and seal for lubrication.
8. Insert the plug into the bracket.
9. Use a 24 mm wrench to hold the plug in place and install the replacement filter.
Hand tighten filter till it contacts O-ring, then tighten 1/2 turn further.
10. Start the prime mover.
Cycle the pump through normal machine operation and check for leaks.
Service Manual
H1P 069—H1P 250 Axial Piston Single Pumps
Minor Repair
54 |
©
Danfoss | September 2020
AX152886482551en-000504